2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 1 WARNING NOTICE
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
__________ Subtask 25-35-00-861-077
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 25-35-00-010-066
B. Get Access
(1) In the galley with the defective/missing flapper door:
-Get access to the galley waste compartment.
EFF : ALL
25-35-00Page 401
4. Procedure
_________ Subtask 25-35-00-040-050
A. Deactivation
(1)
Make sure that no waste and no other items can be put into the galley-waste-compartment.
(a)
If the galley-waste-compartment flapper-door is defective:
-Do a blockage to the galley-waste-compartment flapper-door.
-Make sure that the flapper-door cannot be opened.
-Put a WARNING NOTICE in position to tell persons not to use the galley-waste-compartment.
(b)
If the galley-waste-compartment flapper-door is missing:
-Put a WARNING NOTICE in position to tell persons not to use the galley-waste-compartment.
(2)
Make an entry in the logbook.
5. Close-up
________ Subtask 25-35-00-862-078
A. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
EFF : ALL
25-35-00Page 402
GALLEY EQUIPMENT - ADJUSTMENT/TEST
__________________________________
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
TASK 25-35-00-710-013
Operational Test of the Coffee-Maker
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 24-56-00-710-001 Operational Test of the Galley Supply 38-10-00-614-001 Pressurization of the Potable Water System from a
Ground Air Supply
38-10-00-614-002 Depressurization of the Potable Water System
3. Job Set-up
__________
Subtask 25-35-00-861-062
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
Subtask 25-35-00-860-051
B. Aircraft Maintenance Configuration
(1)
Make sure that the related galley is supplied with electrical power (Ref. TASK 24-56-00-710-001).
(2)
Make sure that the related circuit breaker(s) of the coffee-maker on the galley control panel is(are) closed.
EFF : ALL
25-35-00Page 501
(3) Pressurize the potable water system (Ref. TASK 38-10-00-614-001).
4. Procedure
_________ **ON A/C 001-049, 101-105,
Subtask 25-35-00-710-064-A
A. Do the Operational Test of the Coffee-Maker WARNING : DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT
_______
BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
WARNING : OPEN THE WATER FAUCET OR THE WATER DRAIN CAREFULLY AND SLOWLY.
_______ THE TANK IS PRESSURIZED AND STEAM OR VERY HOT WATER CAN COME OUT OF THE NOZZLE. HOT WATER OR STEAM IS DANGEROUS (IT CAN BURN YOU).
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the coffee-maker:
-Push and hold the LAMP TEST pushbutton.
2. At the galley:
-Close the galley potable-water shutoff-valve.
3. At the coffee-maker:
-
Hold an empty server under the coffee-maker water-faucet and open the faucet.