• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 19:06来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 D.  Procedure
 S 014-015
 (1)  To release the oxygen mask door so the masks will drop, do the following:
 (a)  
For the ASU, put a small tool into the latch access hole.

 (b)  
For the LSU, slide a thin card like object between the oxygen mask door and the ceiling panel over the latch.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-23-13
 ALL  ú ú 02 Page 401 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL

 

LSU SHOWN; ASU SIMILAR
Attendant and Lavatory Service Units (ASU's and LSU's) Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-23-13
 ALL  ú ú 01 Page 402 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 044-018
 WARNING: MAKE SURE YOU INSTALL THE RELEASE PIN OR SAFETY PIN WITH A
_______ WARNING FLAG ON THE GENERATOR. THE OXYGEN GENERATOR IS A PYROTECHNIC-ACTIVATED DEVICE. IF THE RELEASE PIN OR SAFETY PIN IS PULLED AND THE GENERATOR FIRES, THE GENERATOR GETS VERY HOT (450°F OR MORE). IF YOU TOUCH A HOT GENERATOR, YOU WILL GET AN INJURY.
 (2)  
Install a safety pin (Detail A) (AMM 35-22-11/201) to isolate the oxygen generator.

 S 024-003

 (3)
Remove the fasteners in the unit adjacent to the inboard edge.

 S 024-004

 (4)
Move the unit inboard and disconnect the electrical connector.

 S 024-005

 (5)  
Remove the unit.


 TASK 25-23-13-404-006
 3.  ASUs or LSUs Installation_________________________
 A. References
 (1)  
AMM 35-22-11/201, Oxygen Generator

 (2)  
AMM 35-22-31/201, Oxygen Mask


 B. Access
 (1)  Location Zone
 100 Upper Half Fuselage

 C. Procedure
 S 424-007
 (1)  
Connect the electrical connector and put the unit into the opening in the ceiling panel.

 (2)  
Install the fasteners that attach the unit to the panel.


 S 424-008
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-23-13
 ALL  ú ú 02 Page 403 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 444-016
 WARNING: MAKE SURE THE RELEASE PIN IS INSTALLED WITH A WARNING FLAG ON
_______ THE GENERATOR. THE OXYGEN GENERATOR IS A PYROTECHNIC-ACTIVATED DEVICE. IF THE RELEASE PIN IS PULLED AND THE GENERATOR FIRES, THE GENERATOR GETS VERY HOT (450°F OR MORE). IF YOU TOUCH A HOT GENERATOR, YOU WILL GET AN INJURY.
 CAUTION:_______YOU MUST REMOVE THE SAFETY PIN. THE GENERATOR WILL NOT OPERATE IN AN EMERGENCY WITH AN INSTALLED SAFETY PIN.
 (3)  
Remove the safety pin to operate the oxygen generator (Detail A) (AMM 35-22-11/201).

 S 434-010

 (4)  
Put the oxygen mask into the service unit (AMM 35-22-31/201).


 D. Put the Airplane Back to its Usual Condition
 S 864-012
 (1) Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 (a)  P18 Load Control Center
 1) P18-3 OXYGEN SYSTEM PASS R
 2) P18-3 OXYGEN SYSTEM PASS L

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 25-23-13
 ALL  ú ú 02 Page 404 ú Nov 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 PASSENGER CABIN PASSENGER SERVICE UNITS (PSUs) - MAINTENANCE PRACTICES
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 EQUIPMENT/FURNISHINGS(63)