 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking caps
 No specific blanking plugs
 No specific circuit breaker(s) safety clip(s)
 No specific warning notice
 No specific container 10 l (2.6416 USgal)
 No specific access platform 3.5 m (11 ft. 6 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 52-41-00-010-001 Open the APU Doors for Access 49-91-14-991-002 Fig. 401

R  EFF : 001-049, 101-105, 107-107, 151-199, 49-91-14Page 401 201-210, Config-2 Aug 01/05
 CES  3. Job Set-up


__________ Subtask 49-91-14-860-053
 A. Aircraft Maintenance Configuration
 (1)
 Energize the ground service network
 (Ref. TASK 24-42-00-861-001).


 (2)
 On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).

 

 Subtask 49-91-14-865-055
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
 Subtask 49-91-14-010-052
 C. Get Access
 (1)
 Put the access platform in position below the APU access doors 315AL, 316AR.

 (2)
 Open the access doors 315AL and 316AR (Ref. TASK 52-41-00-010-001).

 (3)
 Set the LIGHT control SW 11LJ to the ON position.

 

R  EFF : 001-049, 101-105, 107-107, 151-199, 49-91-14Page 402 201-210, Config-2 Aug 01/05
 CES  4. Procedure


_________
 (Ref. Fig. 401/TASK 49-91-14-991-002) Subtask 49-91-14-020-051
 A. Removal of the Differential Pressure Switches
 (1)
 Disconnect the electrical connectors (5) from the switches (4).

 (2)
 Put blanking caps on the disconnected electrical connectors.

 (3)
 Put a container below the filter housing.

 (4)
 Remove the switches (4) from the oil filter housings (1).

 (5)
 Remove and discard the O-rings (2) and (3).

 (6)
 Install blanking plugs in bottom of oil filter housings (1).

 

R  EFF : 001-049, 101-105, 107-107, 151-199, 49-91-14Page 403 201-210, Config-2 Aug 01/05
 CES


 Differential Pressure Switches
 Figure 401/TASK 49-91-14-991-002

 CES  TASK 49-91-14-400-002


 Installation of the Oil Filter Differential Pressure Switches (8070KM) (131-9(A))
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice No specific access platform 3.5 m (11 ft. 6 in.) No specific Torque Wrench : range 0.20 to 3.60 m.daN
 (2.00 to 26.00 lbf.ft)
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 03-002 GB DEF-STAN 91-101
 LUBRICATING OIL TURBINE ENGINE SYNT BASE
 (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
2 O-ring 49-91-45 70 -060 3 O-ring 49-91-45 70 -070

R  EFF : 001-049, 101-105, 107-107, 151-199, 49-91-14Page 405 201-210, Config-2 Aug 01/05
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER 6(85)