(2)
De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002).
(3)
Remove the warning notice(s).
TASK 49-91-42-200-003 Inspection of the Magnetic Drain Plug (APS 3200) WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS
_______ WHEN YOU DO THE MAINTENANCE TASK(S).
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific source of white light
No specific access platform 3.5 m (11 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific lint-free cloth
Material No. 11-002 USA MIL-PRF-680 DRY CLEANING SOLVENT (VARSOL/WHITE SPIRIT) (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector 49-00-00-860-005 APU Start by External Power (APS 3200) 49-00-00-860-006 APU Shutdown by External Power (APS 3200) 49-11-11-000-003 Removal of the Power Plant (APU) (APS 3200) 49-11-11-400-003 Installation of the Power Plant (APU) (APS 3200) 49-90-00-600-005 Oil Change (Drain Method) (APS 3200) 49-91-41-920-001 Remove and Discard Pressure Oil Filter-Element
(8076KM) (APS 3200) 49-91-41-920-002 Replace AC-Generator Scavenge Filter-Element (8069KM)
(APS 3200) 49-91-42-000-002 Removal of the Magnetic Drain Plug (APS 3200) 49-91-42-400-002 Installation of the Magnetic Drain Plug (APS 3200) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access 49-91-42-991-004 Fig. 202
3. Job Set-up
__________
Subtask 49-91-42-860-053
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
(2)
On the panel 25VU, make sure that the APU MASTER SW pushbutton switch is off.
(3)
Put a warning notice in the cockpit to tell persons not to start the APU.
(4)
Make sure that hydraulic systems are depressurized
(Ref. TASK 29-00-00-864-001).
Subtask 49-91-42-865-058
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
Subtask 49-91-42-010-053
C. Get Access
(1)
Put the access platform in position below the APU access doors 315AL and 316AR.
(2)
Open the APU access doors 315AL and 316AR (Ref. TASK 52-41-00-010-001).
(3)
Set the LIGHT control switch 11LJ to the on position.
4. Procedure
_________
(Ref. Fig. 202/TASK 49-91-42-991-004)
WARNING : USE THE CORRECT PERSONAL PROTECTION.
_______ OIL CAN HAVE ADDITIVE CALLED TRICRESYL PHOSPHATE IN IT. THIS CHEMICAL IS AN ASPHYXIANT, IT IS POISONOUS AND CAN BE ABSORBED THROUGH THE SKIN. USE CARE WHEN ENGINE OIL IS DRAINED. HOT OIL CAN POSSIBLY CAUSE BAD BURNS.
Subtask 49-91-42-240-050
A. Inspection of the Magnetic Drain Plug
(1)
Remove the magnetic element from the drain plug (Ref. TASK 49-91-42-000-002).
(2)
Inspect the magnetic element under a source of white light for metal particles.
(a)
A small quantity of metal particles not larger than 1.50 mm (0.0590 in.) in any dimension is permitted. In this case install the magnetic element in the drain plug (Ref. TASK 49-91-42-400-002).