 DH13PM 1 TANK - ENGINE OIL FILLING UP

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific lint-free cloth


 C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector 49-90-00-600-002 Oil Change (Drain Method) (GTCP 36-300) 49-90-00-600-002 Oil Change (Top-Off Method) (GTCP 36-300) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access 49-90-00-991-001 Fig. 301 49-90-00-991-004 Fig. 302
 3. Job Set-up
__________
 Subtask 49-90-00-860-054
 A. Aircraft Maintenance Configuration
 (1)
 Energize the ground service network
 (Ref. TASK 24-42-00-861-001).


 (2)
 On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).

 

 Subtask 49-90-00-865-050
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41


 Subtask 49-90-00-010-050
 C. Get Access
 (1)
 Put the access platform in position below the APU access door 315AL and 316AR.

 (2)
 Open the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-010-001).


 (3)
 Set the LIGHT control switch 11LJ to the on position. Subtask 49-90-00-869-050

 D.
 Use the oil brands and types which follow: SPECIFICATION - MIL-L-7808, TYPE I


 -------------------------------------------------------------------------------
AMBIENT TEMPERATURE
 APPROVED OIL BRAND-NAME
 MINIMUM ---------------------------------------------------------- MAXIMUM---------------------
Aeroshell 390  -54C (-65F)  54C (130F)
 Brayco 880  -54C (-65F)  54C (130F)
 Castrol 325  -54C (-65F)  54C (130F)
 BP/Exxon Turbo Oil 2389  -54C (-65F)  54C (130F)
 Castrol 399 --------------------------------------- -54C (-65F) ------------------- 54C (130F)---------------------
SPECIFICATION - MIL-L-23699, TYPE II

 -------------------------------------------------------------------------------AMBIENT TEMPERATURE APPROVED OIL BRAND-NAME MINIMUM MAXIMUM -------------------------------------------------------------------------------
Castrol 5000  -40C (-40F)  54C (130F)
 BP/Exxon Turbo Oil 2380  -40C (-40F)  54C (130F)
 BP/Exxon Turbo Oil 2197  -40C (-40F)  54C (130F)
 Hatco 3611  -40C (-40F)  54C (130F)
 Mobil Jet Oil II  -40C (-40F)  54C (130F)
 Mobil Jet Oil 254  -40C (-40F)  54C (130F)
 Mobil Jet Oil 291  -40C (-40F)  54C (130F)
 Aeroshell Turbine Oil 500  -40C (-40F)  54C (130F)
 Aeroshell Turbine Oil 560  -40C (-40F)  54C (130F)
 Aeroshell 555  -40C (-40F)  54C (130F)
 Royco 899  -40C (-40F)  54C (130F) 

 

 -------------------------------------------------------------------------------
AMBIENT TEMPERATURE APPROVED OIL BRAND-NAME Royco 555 -40C (-40F) 54C (130F) Royco Turbine Oil 500 -40C (-40F) 54C (130F) Royco Turbine Oil 560 -40C (-40F) 54C (130F) Castrol 98 -40C (-40F) 54C (130F) -------------------------------------------------------------------------------


 4. Procedure
_________ (Ref. Fig. 301/TASK 49-90-00-991-001, 302/TASK 49-90-00-991-004) NOTE : Two methods are used to replenish the APU, the gravity fill method
____
 and the pressure fill method. Both methods are described in the
 procedures that follow.

 Subtask 49-90-00-612-050
 A. Check Oil Level and Replenish (Gravity Fill Procedure)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER 6(57)