• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 14:47来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-32-49-281-001 Oil Sampling for Analysis 24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector 49-00-00-860-003 APU Start by External Power (GTCP 36-300) 49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300)  -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------


49-90-00-600-001 Check Oil Level and Replenish (GTCP 36-300) 49-91-41-200-001 Remove and discard Alternator Scavenge Filter Element
 (8069KM) (GTCP 36-300) 49-91-42-000-001 Removal of the Drain Plug (8077KM) (GTCP 36-300) 49-91-42-400-001 Installation of the Drain Plug (8077KM) (GTCP 36-300) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access 49-90-00-991-001 Fig. 301
 3. Job Set-up
__________
 Subtask 49-90-00-860-056
 A. Aircraft Maintenance Configuration
 (1)
 Energize the ground service network
 (Ref. TASK 24-42-00-861-001).


 (2)
 On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).

 

 Subtask 49-90-00-865-052
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
 Subtask 49-90-00-010-051
 C. Get Access
 (1)
 Put the access platform below the APU access doors 315AL and 316AR.

 (2)
 Open the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-010-001).

 (3)
 Set the LIGHT control switch 11LJ to the on position.

 


 4. Procedure
_________
 (Ref. Fig. 301/TASK 49-90-00-991-001) Subtask 49-90-00-612-053
 A. Oil Change
 (1)
 Position the container below the magnetic drain plug (8077KM) (8).

 (2)
 Push in the filler cap (2) to release the pressure.

 (3)
 Turn the filler cap (2) counterclockwise and remove, to let the oil drain correctly.

 (4)
 Remove the magnetic drain plug (8077KM) (8) (Ref. TASK 49-91-42-000-001) and drain the oil into the container.


 NOTE : If you think that the condition of the drained oil is not
____ correct, do a sampling of the APU oil for analysis (Ref. TASK 12-32-49-281-001).
 (5)
 Install the magnetic drain plug (8077KM) (8) (Ref. TASK 49-91-42-400-001).

 (6)
 Change the oil pump and generator filters (Ref. TASK 49-91-41-200-001).

 (7)
 Replenish the oil system (Ref. TASK 49-90-00-600-001).


 (8)
 Remove the container. Subtask 49-90-00-410-052

 B.
 Close Access

 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the APU access doors 315AL, 316AR (Ref. TASK 52-41-00-410-001).

 

 


 Subtask 49-90-00-865-053
 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD
 Subtask 49-90-00-790-051
 D. Test
 (1)
 Operate the APU for five minutes (Ref. TASK 49-00-00-860-003) and (Ref. TASK 49-00-00-860-004).

 (2)
 Open the access door 315AL.

 (3)
 Examine the magnetic drain plug and oil filters area for evidence of oil leaks. NOTE: No leaks are permitted.


 5. Close-up
________ Subtask 49-90-00-410-053
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Set the LIGHT control switch 11LJ to the off position.


 (3)
 Close the APU access door 315AL (Ref. TASK 52-41-00-410-001). Subtask 49-90-00-860-057

 B.
 Aircraft Maintenance Configuration
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER 6(60)