(2)
On the panel 25VU, make sure that the APU MASTER SW p/bsw is OFF.
(3)
Put a warning notice in the cockpit to tell persons not to start the APU.
(4)
Make sure that hydraulic systems are depressurized
(Ref. TASK 29-00-00-864-001).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-91-42Page 210 201-210, Config-2 Aug 01/05
CES Subtask 49-91-42-865-066
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
Subtask 49-91-42-010-055
C. Get Access
(1)
Put the access platform below the APU compartment.
(2)
Open the APU access doors 315AL, 316AR and (Ref. TASK 52-41-00-010-001).
(3)
Set the LIGHT SW 11LJ to the ON position.
4. Procedure
_________ (Ref. Fig. 201/TASK 49-91-42-991-005, 202/TASK 49-91-42-991-006) Subtask 49-91-42-210-052
A. Removal and Inspection Check of the Magnetic Drain Plug.
(1)
Put the container to the position below the drain plug (1).
(2)
Push the drain plug (1) and turn it to remove from the gearbox.
(3)
Remove and discard the packing (2) from the drain plug (1).
(4)
Inspect the Magnetic Drain Plug (1) for signs of metal particles.
(5)
A small amount of thin metal slivers, swarf or fines is acceptable and the APU can continue in service.
NOTE : No silver material (silver-plated steel flakes) is permitted.
____
R EFF : 001-049, 101-105, 107-107, 151-199, 49-91-42Page 211 201-210, Config-2 Aug 01/05
CES
Magnetic Drain Plug
Figure 202/TASK 49-91-42-991-006
CES
(6)
If metal particles (other than shiny metal) are moderately collected on the magnetic plug
-Clean and install the magnetic drain plug (Ref. TASK 49-91-42-400-003);
-Start and operate the APU for at least 15 minutes (Ref. TASK 49-00-00-860-008);
-Remove the magnetic drain plug (Ref. TASK 49-91-42-000-003) an do a check for metal particles.
(7)
If a medium quantity of particles, not including silver-plated steel, is found on the Magnetic Drain Plug, following procedures are necessary:
(a) Inspect the generator scavenge oil filter (Ref. TASK 49-91-41-200-002).
(b)
Inspect the lube pump oil filter (Ref. TASK 49-91-41-200-002). Subtask 49-91-42-420-055
B.
Installation of the Magnetic Drain Plug.
(1)
Lubricant the new packing (2) with OILS (Material No. 03-002)
(2)
Install the new O-ring (2) on the magnetic drain plug.
(3)
Install the magnetic drain plug in the gearbox.
(4)
Close the APU access doors (Ref. TASK 52-41-00-410-001). Subtask 49-91-42-865-067
C.
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD
Subtask 49-91-42-710-053
D. Start and operate the APU.
(1)
Start the APU (Ref. TASK 49-00-00-860-008).
(2)
Allow the APU to run for 5 minutes.
(3)
Shutdown the APU (Ref. TASK 49-00-00-860-009).
(4)
Open the APU access doors 315AL/316AR (Ref. TASK 52-41-00-010-001).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-91-42Page 213 201-210, Config-2 Aug 01/05
CES
(5)
Check the magnetic drain plug for leaks.
NOTE : No leakage is permitted.
____
(6)
Do a visual check of the oil quantity in the APU. Add oil if the oil level is on or less than the ADD mark on the sight glass (Ref. TASK 49-90-00-600-007).
5. Close-up
________ Subtask 49-91-42-410-056
中国航空网 www.aero.cn
航空翻译 www.aviation.cn