21-58-01
 ALL  ú ú 02F Page 410 ú Feb 15/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 
MAINTENANCE MANUAL
 (2)  
AMM 25-57-04/401, Roller/Caster Trays
 (3)  
AMM 25-58-01/401, Lock/Stop Roller/Caster Trays
 (4)  
AMM 25-58-03/401, Vertical and Side Restraint/Caster Unit
 (5)  
AMM 53-21-02/401, Main and Upper Deck Floor
 (6)  
AIPC 21-58-01 Fig. 1
 (7)  
AIPC 21-58-01 Fig. 2
 (8)  
SSM 21-58-07
 (9)  
WDM 21-58-26
 B. Access
 (1)  Location Zone
 151 Area Aft of Bulk Cargo Compartment, LH
 C. Procedure
 S 034-049
 (1)  
Remove the covers from the duct openings.
S 424-050
 (2)  
Put the fan in its position.
 (a)  Make sure the flow arrow points in the inboard direction.
 S 434-051
 (3)  
Install the two clamps that attach the fan to the airplane structure.
S 434-052
 (4)  
Pull the sleeve with the air outlet tube onto the inboard (outlet) side of the fan.
S 434-053
 (5)  
Pull the sleeve onto the outboard (inlet) side of the fan.
S 434-054
 (6)  
Install the two clamps that attach the sleeves to both ends of the fan.
S 434-055
 (7)  
Install the electrical connector to the fan.
 (a)  
Primary fan, DB8599
 (b)  
Alternate fan, DB8598
 S 864-056
 (8)  Remove the "DO-NOT-CLOSE" identifiers and close these circuit breakers:
 (a)  Main power distribution panel, P6
 1) 6H30, AFT EQUIP COOL FAN CONT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 21-58-01
 ALL  ú ú 02F Page 411 ú Feb 15/99 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A 
747-400 MAINTENANCE MANUAL
 (b)  P84 Panel
 1) PRI AFT EQUIP COOL FAN PWR
 2) ALT AFT EQUIP COOL FAN PWR
 D. Do a Check of the Fan Installation
 S 864-057
 (1)  
Supply electrical power (AMM 24-22-00/201).
S 714-058
 (2)  
Do these steps for the primary fan:
 (a)  
Make sure the fan operates.
 (b)  
Make sure there are no large leaks in the fan to duct connections.
 S 714-059
 (3)  Do these steps for the alternate fan:
 (a)  
Open this circuit breaker on the P84 panel:
 1) PRI AFT EQUIP COOL FAN PWR
 (b)  
Make sure that within 15 seconds the alternate aft fan operates.
 NOTE: Ther primary fan will stop.
____
 (c)  
Make sure there are no large leaks in the fan to duct connections.
 (d)  
Close this P84 panel circuit breaker:
 1) PRI AFT EQUIP COOL FAN PWR
 E. Put the Airplane Back to its usual Condition
 S 414-060
 (1)  Do these steps if you removed the floor panels to get access to the fans:
 (a)  
Install the floor panel that you removed (AMM 53-21-02/401).
 (b)  
Install the following cargo handling equipment on the floor panels: 1) Roller/Caster Trays (AMM 25-57-04/401) 2) Lock/Stop Roller/Caster Trays (AMM 25-58-01/401) 3) Vertical and Side Restraint/Caster Unit (AMM 25-58-01/401)
 S 864-061
 (2)  Remove the electrical power if it is not necessary
 (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 21-58-01
 ALL  ú ú 01F Page 412 ú Feb 10/94 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 2(85)