 F. Clean the Temperature Sensor Assembly
 S 147-005
 (1)  
Clean the temperature sensor and the temperature bulb with a clean cloth that is moist with solvent.

 S 177-013

 (2)  
Rinse the solvent from the parts with a clean cloth that is moist with water.

 S 147-014

 (3)  
Dry the temperature bulb and the temperature sensor with a clean dry cloth.


 S 147-018
 CAUTION: DO NOT LET THE CLEANING SOLUTION GET INTO THE FAN MOTOR
_______
 HOUSING. THE SOLUTION CAN CAUSE DAMAGE TO THE MOTOR'S
 ELECTRICAL WIRING.

 (4)  
Clean the internal and external surfaces of the housing, motor and fan blades with a clean cloth or soft bristle brush and solvent.

 S 147-015

 (5)  
Remove all the solvent from the sensor assembly with a clean dry cloth.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-61-03
 ALL  ú ú 04 Page 702 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 G.  Assemble the Temperature Sensor Assembly
 S 437-007
 (1)  Install the sensor fan on the housing as follows:
 (a)  
Put the sensor fan on the housing in the position noted in step 2.E.(4)(a).

 (b)  
Turn the three clamps intil they are in position over the housing flange.

 (c)  
Tighten the screws on all three clamps.


 1)  For an aluminum housing, tighten the screws to 4 - 5 pound-inches (5.4 - 6.8 newton-meters) above the run-on torque.
 2)  For a plastic housing, tighten the screws to 2 - 3 pound-inches (2.7 - 4.1 newton-meters) above the run-on torque.
 S 437-016
 (2)  Install the temperature sensor in the housing so that the key lock on the temperature sensor points to the fan motor.
 (a)  Install and tighten the two screws through the sensor flange and housing. 1) For an aluminum housing, tighten the screws to 8 - 10
 pound-inches (10.9 - 13.6 newton-meters) above the run-on torque.
 2)  For a plastic housing, tighten the screws to 2 - 3 pound-inches (2.7 - 4.1 newton-meters) above the run-on torque.
 S 437-008
 (3)  
Install the temperature bulb in the housing. Tighten the
 temperature bulb to 10 - 20 pound-inches (13.6 - 27.1
 newton-meters).


 S 437-017

 (4)  
Install the lockwire to secure the temperature bulb in it's boss (AMM 20-11-28/401).

 (5)  
Install the temperature sensor assembly (AMM 21-61-03/401).


 S 427-011
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-61-03
 ALL  ú ú 03 Page 703 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 CARGO COMPARTMENT TEMPERATURE SENSOR ASSEMBLY - REMOVAL/INSTALLATION
____________________________________________________________________
 1.  General_______
 A.  You must do a test of the sensor after you install it.
 B.  The temperature sensor assembly for the forward cargo is on the
 compartment left sidewall opposite of the forward cargo door.

 C.  The temperature sensor assembly for the aft cargo is on the compartment right sidewall forward of the aft cargo compartment door.
 D.  The temperature sensor assembly for the bulk cargo is on the compartment left sidewall opposite of the bulk cargo door.
 TASK 21-61-05-004-001
 2.  Temperature Sensor Assembly Removal (Fig. 401)___________________________________
 A.  References
 (1)  
IPC 21-43-02 Fig. 01

 (2)  
SSM 21-42-01, 21-61-08


 B.  Access
 (1)  Location Zone 121 Forward Cargo Comartment Forward Half, LH 142 Aft Cargo Compartment, RH 145 Bulk Cargo Compartment, LH
 C.  Procedure
 S 864-002
 (1) Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  
P6, Main Power Distribution Panel 1) 6G33, ZONE TEMP SENSOR LWR CARGO 2) 6F28, ZONE TEMP CONT AC 3) 6F29, ZONE TEMP CONT DC 4) 6F35, PACK TEMP CONT A 5) 6F36, PACK TEMP CONT B
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 2(131)