• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:18来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (e)  
Push the NEXT PAGE key until you find <21 AIR CONDITIONING.

 (f)  
Push the LSK that is adjacent to <21 AIR CONDITIONING to show the GROUND TESTS menu for the air conditioning system.

 (g)  
Push the NEXT PAGE key until you find <SHUTOFF / DUMP VLV

 NOTE:  If INHIBITED shows above <SHUTOFF / DUMP VLV the test will not operate.

 (h)  
If INHIBITED shows above <SHUTOFF / DUMP VLV: 1) Push the LSK that is adjacent to the test prompt. 2) Do the steps shown on the CDU. 3) Push the LSK that is adjacent to <RETURN to show the ground

 


 test menu again.
 S 714-004
 (4)  Push the LSK that is adjacent to SHUTOFF / DUMP VLV.
 (a)  
When the TEST PRECONDITIONS page shows, make sure each instruction on the page is completed. (Push the NEXT PAGE key to see subsequent pages.)

 (b)  
Push the LSK that is adjacent to START TEST>.


 NOTE:  IN PROGRESS shows during the test.
____
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-02
 ALL  ú ú 02F Page 406 ú Feb 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 714-005
 (5)  When IN PROGRESS goes out of view, look for PASS or FAIL> adjacent to <SHUTOFF / DUMP VLV
 NOTE: If a PASS indication shows, no failures occurred during the
____
 test.

 (a)  If FAIL> shows: 1) Push the LSK that is adjacent to FAIL> to see the GROUND TEST MSG pages for the failure. 2) Push the NEXT PAGE key until you find all the GROUND TEST MSG pages. 3) Make a list of all CMCS messages, CMCS message numbers, and ATA numbers that show on the GROUND TEST MSG pages.
 4)  Go to the CMCS Message Index of the Fault Isolation Manual (FIM) to find the corrective action for each CMCS message.
 S 794-005
 (6)  Do a leak check of the valve installation:
 (a)  
Supply pneumatic power (AMM 36-00-00/201).

 (b)  
Put the applicable PACK selector (1 or 3), on the P5 panel, to the NORM position.

 (c)  
Feel for leaks around the valve.
 1) Small leaks are permitted.
 2) You must repair a large leak.

 

 E.  Put the Airplane Back to its Usual condition
 S 414-006
 (1)  
Close the applicable access door, 191H-L or 191H-R
 (AMM 06-09-03/201).


 S 864-010

 (2)  
Turn the applicable PACK selector, on the P5 panel, to the OFF position.

 S 864-012

 (3)  
Release the pressure in the pneumatic system, if it is not necessary (AMM 36-00-00/201).

 S 864-014

 (4)  
Remove the electrical power, if it is not necessary
 (AMM 24-22-00/201).

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-51-02
 ALL  ú ú 01F Page 407 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 HEAT EXCHANGER - REMOVAL/INSTALLATION
_____________________________________
 1.  General_______
 A.  This procedure has instructions to remove and install the heat exchangers. A heat exchanger is installed in each air cooling pack. The heat exchanger, the ram-air outlet door, and the ram-air outlet door actuator must be removed and installed as a unit.
 TASK 21-51-03-004-001
 2.  Heat Exchanger Removal (Fig. 401)______________________
 A.  Special Tools and Equipment
 (1)  
ME65B40000-1 Heat Exchanger Lifting Tool

 (2)  
2ME65B40006 Heat Exchanger Lifting Tool


 B.  References
 (1)  
AMM 06-09-03/201, Body Section 44 Access Doors and Panels

 (2)  
AMM 21-62-05/401, Ram Air Exit Door Actuator

 (3)  
AMM 21-62-12/401, Ram Air Exit Door Limit Switch

 (4)  
AMM 36-00-00/201, Pneumatic System

 (5)  
AMM 45-10-00/201, Central Maintenance Computer System
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn