• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:18来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

CLEANER PURGE LINE  SUPPLY VALVE INBOARD  FAN AIR  FAN EXHAUST FROM  E6/E9 VALVE 
RACKS TO E6/E9 
FORWARD EQUIPMENT COOLING SUPPLY COMPONENTS 

Equipment Cooling System - Component Location
Figure 1 (Sheet 2)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-58-00
 ALL  ú ú 01F Page 3 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
D11804
A
747-400
MAINTENANCE MANUAL

DECK FLIGHT  FLIGHT DECK OVERHEAD 
FAN EXHAUST 
MAIN EQUIPMENT CENTER  PANELS  CHECK VALVE 
VALVE EXHAUST INBOARD 
PANELS  GROUND EXHAUST VALVE 
FWD 
BYPASS TO VALVE 
FORWARD EQUIPMENT COOLING EXHAUST COMPONENTS B  TO FORWARD CARGO COMPARTMENT 
Figure 1 (Sheet 3) Equipment Cooling System - Component Location 

D11806
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-58-00
 ALL  ú ú 01F Page 4 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

TEMPERATURE CONTROL PANEL (P5)
SEE D
EQUIPMENT COOLING CARD
ELECTRICAL SYSTEMS CARD FILE
SEE C
ELECTRICAL SYSTEMS CARD FILE
C
FAN  FLT  TEMP  FWD  MAIN  AFT 
DECK  AUTO  AUTO  DECK  AUTO 
ON  TEMP 

CW
MAN CW CW
MAN MAN
FWD LOWER AFT ZONE RST TRIM AIR
AUTO LOBE AUTO TEMP ON
SYS FAULTa
CW CW EQUIP COOLING
MAN MAN EQUIPMENT
NORM
COOLING SYSTEM
HI FLOW PACK RST  AFT CARGO HT STBY OVRD
SELECTOR ON
ON
SYS TEMPFAULTa
a
TEMPERATURE CONTROL PANEL (P5)
D
Equipment Cooling System - Component Location Figure 1 (Sheet 4)
D11817
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-58-00
 ALL  ú ú 01F Page 5 ú Oct 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

747-400
MAINTENANCE MANUAL

AREA BEHIND BULK CARGO COMPARTMENT
SEE E
DOOR 5 (REF)
MAIN DECK FLOOR
FWD  AFT EQUIPMENT COOLING FANS 
CARGO COMPARTMENT AREA BEHIND BULK 

Figure 1 (Sheet 5) Aft Equipment Cooling System - Component Location 

D11755
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-58-00
 ALL  ú ú 01F Page 6 ú Oct 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 B.  The E6/E9 valve controls flow of equipment cooling air to the E6 and E9 racks in the center equipment bay. The valve is a butterfly type valve actuated by a dual coil latching solenoid. The E6/E9 valve is powered by 28 volt dc from the 28 vdc MN BAT BUS. The valve has a manual override that also shows the position of the valve.
 C.  The E6/E9 valve controls flow of equipment cooling air to the E6 and E9 racks in the center equipment bay. The valve is a butterfly type valve actuated by a dual coil latching solenoid. The E6/E9 valve is powered by 28 volt dc from the 28 vdc MN BAT BUS.
 D.  The valve has a manual override that also shows the position of the valve.
 6.  3-way Valve
___________
 A.  The equipment cooling 3-way valve supplies conditioned pack air to the flight deck instruments when at least two packs are operating.
 B.  The 3-Way valve is an electrically operated, 115 VAC two position valve. When open, conditioned air is supplied to the flight deck. When closed, equipment cooling supply fan air is supplied to the flight deck.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 空调 AIR CONDITIONING 2(56)