 a) 415R14, EQUIP COOL EXHAUST FAN POWER (ag) Make sure the exhaust fan is now off but the supply fan is still on. (ah) Make sure the bypass valve (V446) is now open and the ground exhaust valve (V447) is closed. (ai) Make sure that air does not flow from the heat ducts below the forward cargo floor. (aj) Make sure the Ground Test Enable switch on the P461 panel is in
 the ENABLE position.
 (ak) Make sure the EICAS status message EE CLNG EXH FAN is shown.
 (al) To restore exhaust fan power, close this circuit breaker and remove the DO-NOT-CLOSE tag: 1) Right Power Distribution Center Panel, P415 a) 415R14, EQUIP COOL EXHAUST FAN POWER
 (am) Open and then close the following circuit breaker to cycle power control for the exhaust fan: 1) DC Power Distribution Panel, P180 a) 180H30, EQUIP COOL CONT EXH FAN
 (an) Put the EQUIP COOLING mode selector on the P5 panel to OVRD for 5 seconds then return back to the NORM position to reset system.
 (ao) Make sure that the exhaust fan and the supply fan are on (listen for the sound of each fan).
 (ap) Make sure there are no EICAS messages shown for the Equipment Cooling system.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-58-00
 ALL  ú ú 04 Page 508 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 E. Put the Airplane to its Usual Condition
 S 865-172
 (1)  
Do the procedure to put the Air/Ground Relay System back to the ground mode (AMM 32-09-02/201).

 S 865-088

 (2)  
Remove the electrical power, if it is not necessary
 (Ref 24-22-00/201).

 

 TASK 21-58-00-705-062
 5. Operational Test - Low Flow Detector Test
_________________________________________
 A. References
 (1)  24-22-00/201, Manual Control
 B. Access
 (1)  Location Zone 121 Forward Cargo Compartment Forward Half, LH
 C. Prepare for the Test
 S 865-063
 (1)  
Supply electrical power (Ref 24-22-00/201).

 S 865-064

 (2)  
Make sure the EQUIP COOLING selector, on the P5 panel, is in the NORM position.


 D. Do the Test
 S 715-009
 (1)  Do a test of the low flow (cooling effect) detectors.
 CAUTION: DO NOT LET BOTH FANS STAY OFF FOR MORE THAN FIVE MINUTES.
_______ EXTENDED OPERATION OF AIRPLANE SYSTEMS WITHOUT COOLING AIRFLOW CAN RESULT IN DAMAGE TO EQUIPMENT.
 (a)  Open the circuit breaker 414R30 EQPT COOLING SUPPLY FAN on P414 power distribution center-left.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-58-00
 ALL  ú ú 04 Page 509 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b)  
Open the circuit breaker 415R14 EQPT COOLING EXH FAN on P415 power distribution center-right.

 (c)  
Make sure that in approximately 70 seconds these messages are shown:

 ~.................................................. | EICAS Caution | EQUIP COOLING | .................................................... | EICAS Status | EQUIP LOW FLOW | .................................................... | EICAS Status | FLT DK LOW FLOW | .................................................... | EICAS Status | EE CLNG SUP FAN | .................................................... | EICAS Status | EE CLNG EXH FAN | 2.......................…..........................1

 (d)  
Close the circuit breaker 414R30 EQPT COOLING SUPPLY FAN on P414 power distribution center-left.

 (e)  
Close the circuit breaker 415R14 EQPT COOLING EXH FAN on P415 power distribution center-right.

 (f)  
Set the EQUIP COOLING switch on the P5 overhead panel to OVRD, then back to NORM.

 (g)  
Make sure there are no equipment cooling messages shown on EICAS.

 (h)  
Make sure the ground crew call horn is off.


 E. Put the Airplane to its Usual Condition
 S 865-012
 (1)  Remove the electrical power, if it is not necessary (Ref 24-22-00/201).
 TASK 21-58-00-705-120
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn