S 722-035
(10)
Move the bypass lever to the open position and hold it open for a minimum of five seconds.
S 842-036
(11)
Release the bypass lever on the fuse, allow the lever to go back to the closed position and install the lockwire.
NOTE: The Decoto hydraulic fuse does not have lockwire installed on
____ the lever.
S 722-037
(12)
Do the test at each of the four brake locations.
S 722-038
(13)
Make sure that the quantity of fluid collected in the container from all four brakes is not more than 1.50 gallons.
S 842-039
(14)
Fill the hydraulic reservoir of system B (AMM 12-12-00/301).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-41-00
ALL ú ú 01 Page 206 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
F. Alternate Brake System Test
S 842-040
(1)
Remove the screw from the end of the bleed fitting on the brake and install the bleed hose in the end of the fitting.
S 492-041
(2)
Put a container (with a minimum capacity of two U.S. gallons) below the bleed fitting of the brake to make sure that the fluid will drain directly into the container.
S 842-042
(3)
Remove the pressure from hydraulic system B (AMM 29-15-00/201).
S 842-043
(4)
Push the brake pedals to the maximum position to apply full brake pressure.
NOTE: The parking brake can be used to keep the brake pedals pushed
____
during the check.
S 722-044
(5)
While full brake pressure is applied, open the brake bleeder valve and let the fluid drain into the container until the flow stops.
S 722-045
(6)
Make sure that the quantity collected in the container is
42-80 cubic inches or approximately 0.18 to 0.35 gallons.
(7)
Close the bleeder valve and remove the bleed hose.
S 432-047
(8)
Tighten the bleeder valve to 40 pound-inches and install the bleed screw and the washer.
S 842-046
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
32-41-00
ALL ú ú 01 Page 207 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 842-048
(9) Remove the lockwire on the bypass lever of the hydraulic fuse that you do a test on.
NOTE: The Decoto hydraulic fuse does not have lockwire installed on
____
the lever.
S 722-049
(10)
Move the bypass lever to the open position and hold it open for a minimum of five seconds.
S 842-050
(11)
Release the bypass lever on the fuse, allow the lever to go back to the closed position and install the lockwire.
NOTE: The Docoto hydraulic fuse does not have lockwire installed on
____
the lever.
S 722-051
(12)
Do the test at one brake on each main landing gear.
S 722-052
(13)
Make sure that the quantity of the fluid collected in the container from the two brakes is not more than 0.70 gallons.
(14)
Fill the system A reservoir (AMM 12-12-00/301).
(15)
Put the airplane back to its usual condition.
S 842-053
S 842-054
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 起落架 LANDING GEAR 3(10)