(s)
Disconnect the bonding jumper for the nozzle from the ground jack on the airplane.
(t)
Put the cap on the fueling receptacle.
(u)
Close the access door, 6540, for the refuel station (P15 panel).
(v)
If you opened the fuel crossfeed valve, move the manual override lever to the CLOSE position to close the fuel crossfeed valve on the right wing rear spar.
S 092-116
WARNING: YOU MUST CAREFULLY DO THE STEPS IN THE TASK BELOW TO REMOVE
_______ THE LE FLAP SAFETY LOCKS. THE LE FLAPS CAN MOVE QUICKLY IF YOU DO NOT INSTALL THE SAFETY LOCKS CORRECTLY. THIS CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
(16) Remove the flap locks from the leading edge flaps (AMM 27-81-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-23-00
ALL ú ú 01 Page 227 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 862-215
WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF THE LE AND TE
_______ FLAPS AND FLAP DRIVE MECHANISMS BEFORE YOU MOVE THE FLAPS. THE FLAPS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
(17)
Retract the leading edge flaps (AMM 27-81-00/201).
S 682-083
(18)
Do this procedure: "Drain the fuel from the sumps" for the applicable tank.
TASK 28-23-00-652-084
3. Fuel Transfer from One Tank to a Different Tank
_______________________________________________
A. General
(1)
If it is necessary to defuel only one of the tanks, you can move the fuel from that tank to a different tank. For example, you can use this procedure when you must repair a fuel leak. The procedure is almost the same as the procedure to defuel the tank with the boost pumps.
(2)
Make sure you monitor the fuel quantity in each tank when you move the fuel from one tank to a different tank.
B. References
(1)
AMM 24-22-00/201, Manual Control
(2)
AMM 49-11-00/201, APU Power Plant
C. Access
(1)
Location Zones
101 Control Cabin Left
102 Control Cabin Right
(2)
Access Panels
6535 Defueling Access Panel
6540 Refueling Station Access Door
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-23-00
ALL ú ú 02 Page 228 ú Jul 12/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
D. Procedure
S 862-085
(1) Connect the external electrical power to the airplane
(AMM 24-22-00/201).
NOTE: If you are not scheduled to defuel the No. 1 tank fully,
____ you can supply power with the APU (AMM 49-11-00/201). Do a check for minimum fuel quantities and other data before you start the APU.
S 862-086
(2)
Make sure all of the circuit breakers for the fuel system on the P6 panel are closed.
S 862-087
(3)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
(a) P6 Main Power Distribution Panel
1) ENG 1 R IGN
2) ENG 1 L IGN
3) ENG 2 R IGN
4) ENG 2 L IGN
S 862-129
(4) If you are scheduled to move fuel from the No. 2 tank to the No. 1 tank or the center tank, make sure the crossfeed valve switch is in the CLOSE position.
NOTE: When you move fuel from tank to tank irregular fuel
____
quantity is satisfactory and permitted.
S 862-130
(5)
If you are not scheduled to move fuel from the No. 2 tank to the No. 1 tank or the center tank, set the crossfeed valve switch to the OPEN position.
(6)
Open the access door, 6540, for the refuel station (Fig. 201).
S 712-091
(7)
Set the fueling valve switches to OPEN to make sure the valve position lights operate correctly.
S 012-090
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 燃油 FUEL 3(27)