S 024-005
(4)
Hold the locking cap and pull the fuel temperature bulb out of the bulb housing.
TASK 28-43-11-404-006
3. Fuel Temperature Bulb Installation (Fig. 401)
__________________________________
A. Equipment
(1) Splices - moistureproof, to connect wires
B. Consumable Materials
(1) D00254 - Grease, Silicone, Dow Corning No. 4 (for use with the Lewis fuel temperature bulb (P/N 67B28A))
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-43-11
ALL ú ú 02 Page 401 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
MINIMUM
Fuel Temperature Bulb Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-43-11
ALL ú ú 01 Page 402 ú Jul 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
C.
D.
E.
A
737-300/400/500MAINTENANCE MANUAL
(2)
G00034 Cheesecloth - New, clean, dry, lint freeReferences
(1)
AMM 24-22-00/201, Manual Control
(2)
SWPM 20-30-12Access
(1)
Location Zones 101 Control Cabin Left 102 Control Cabin Right 310 Left Main Landing Gear
Procedure
S 644-007
(1) Fill the bulb housing with grease.
NOTE: It is not not necessary to apply grease if the fuel
____
temperature is made by Norwich (P/N 10-62247-1).
(a) If you replace a Lewis fuel temperature bulb (P/N 57B28A) with a Norwich fuel temperature bulb (P/N 10-62447-1), remove the grease around the bulb housing with a clean, lint free cloth.
S 434-008
(2)
Hold the temperature bulb by the locking cap.
S 424-009
(3)
Put the fuel temperature bulb into the bulb housing.
S 434-010
(4)
Push the fuel temperature bulb into the housing until it touches the pin.
S 434-011
(5)
Turn the locking cap to lock it around the pin.
S 434-012
(6)
Make a splice from the wires on the fuel temperature bulb to the airplane wire bundle (SWPM 20-30-12).
(a)
Use the applicable crimp tool to connect the wires
(SWPM 20-30-12).
(b)
Put two layers of tape on the connection to give protection from water and fuel (Fig. 401).
S 864-013
(7) Close this circuit breaker and remove the DO-NOT-CLOSE tags:
(a) P6 Main Power Distribution Panel
1) TEMP IND
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-43-11
ALL ú ú 02 Page 403 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(8) S 864-014Supply electrical power (AMM 24-22-00/201).
(9) S 714-015Do this task: Fuel Temperature Indicating System Test (AMM 28-43-00/501).
S 864-016
(10) Remove the electrical power if it is not necessary for other tasks (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-43-11
ALL ú ú 02 Page 404 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
1.
2.
3.
A
737-300/400/500MAINTENANCE MANUAL
FUEL TEMPERATURE INDICATOR - REMOVAL/INSTALLATION
_________________________________________________General
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 燃油 FUEL 3(170)