• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 19:09来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (e)  
Move the LIGHTS switch on the pilots' center panel (P2) to the BRT position (while the OVHT TEST switch is held).

 (f)  
Make sure that the intensity of the lights is bright.

 (g)  
Push one of the two MASTER CAUTION lights.

 (h)  
Make sure that the MASTER CAUTION lights and the AIR COND annunciator light go off.

 (i)  
Release the OVHT TEST switch.

 (j)  
Make sure that the two WING-BODY OVERHEAT lights on the P5-10 panel go off.


 E. Put the Airplane Back to its Usual Condition
 S 865-014
 (1)  Remove electrical power if it is no longer necessary (AMM
 24-22-00/201).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-18-00
 ALL  ú ú 01 Page 502 ú Jul 15/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 WING AND LOWER AFT BODY OVERHEAT DETECTION SENSING ELEMENT -
____________________________________________________________ REMOVAL/INSTALLATION
____________________
 1.  General_______
 A.  This section contains six tasks. The first task is the removal of the overheat sensor element in the wing and lower aft body. The second task is the installation of the sensor element. The third task is the removal of the aft keel beam overheat detection element. The fourth task is the installation of the aft keel beam overheat detection element. The fifth task is the removal of the right wing leading edge overheat detector. The sixth task is the installation of the right wing leading edge overheat detector.
 B.  The minimum element bend radius is one inch. The best bend radius is three inches.
 C.  The sensor element must be straight and away from the connector for one inch before bending.
 TASK 26-18-11-034-001
 2.  Remove the Wing and Lower Aft Body Overheat Detection Sensor Element____________________________________________________________________ (Fig. 401)
 A.  Equipment
 (1)  Bonding meter (AMM 20-22-01/601)
 B.  References
 (1)  
SWPM 20-20-00, Standard Wiring Practices Manual

 (2)  
AMM 26-18-00/201, Wing and Lower Aft Body Overheat Detection System

 (3)  
AMM 26-18-00/501, Wing and Lower Aft Body Overheat Detection System


 C.  Access
 (1)  Location Zones
 218 Aft Cargo
 303/403 Wing Inboard Leading Edge

 D.  Procedure
 S 014-002
 (1)
Open the OVHT WHL WELL WING BDY circuit breaker on panel P6-2.

 S 034-029

 (2)  
Disconnect the electrical connectors at each end of the sensor element.

 S 024-003

 (3)  
Put covers on the open end of the electrical connectors with tape or caps to prevent damage.

 S 024-004

 (4)  
Start at one end and remove the sensor element from each mounting clip.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-18-11
 ALL  ú ú 01 Page 401 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL

DETECTORS OVERHEAT  LEFT AIR  DETECTOR 
CONDITIONING 
PACK OVERHEAT 
DETECTORS 

Wing and Lower Aft Body Overheat Detection Sensing Element Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-18-11
 ALL  ú ú 01 Page 402 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
FWD
RIGHT WING LEADING EDGE OVERHEAT DETECTOR
SHORT DETECTOR ELEMENT LONG DETECTOR ELEMENT

Wing and Lower Aft Body Overheat Detection
Figure 402

E36612
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH TWO SUPPORT TUBES ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(77)