• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 19:09来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 module.
 S 865-044
 (13) Close the FIRE PROTECTION DETECTION ENG NO 2 circuit breaker.
 (a)  Make sure these lights go off: 1) FAULT light on the P8-1 panel. 2) the loop A and loop B INOP lights for ENG NO. 2 on the M279
 module.
 S 865-057
 (14)
 Set the two OVHT DET switches in the A position.

 S 865-058

 (15)
 Move the test switch on the P8-1 panel to the FIRE/OVHT position.


 (a)  Make sure these fire handle lights come on:
 1) ENG 1 OVERHEAT

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-51
 ALL  ú ú 04 Page 506 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 2) ENG 2 OVERHEAT 3) the fire switch handle for engine 1 4) the fire switch handle for engine 2 5) the fire switch handle for the APU
 S 865-059
 (16)
 Set the two OVHT DET switches in the B position.

 S 865-060

 (17)
 Set the test switch on the P8-1 panel in the FIRE/OVHT position.


 (a)  Make sure these fire handle lights come on:
 1) ENG 1 OVERHEAT
 2) ENG 2 OVERHEAT
 3) the fire switch handle for engine 1
 4) the fire switch handle for engine 2
 5) the fire switch handle for the APU

 S 865-061
 (18) Set the two OVHT DET switches in the NORMAL position.
 G. Fire Switch Handle Test
 S 865-062
 (1)  
Set the selector switch on the DC voltmeter on the P5 panel in the TEST position.

 S 865-063

 (2)  
On the test module, M400, set the switches S1 and S2 to the 2 and A positions.


 (a)  Make sure the DC voltmeter shows 28 volts.
 S 865-064
 (3)  Set the S2 switch on the M400 module to the B position.
 (a)  Make sure the DC voltmeter shows 28 volts.
 S 865-065
 (4)  Set the S2 switch on the M400 module to the C position.
 (a)  Make sure the DC voltmeter shows 28 volts.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-51
 ALL  ú ú 04 Page 507 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 755-066
 (5)  Make sure the start switches are in the OFF position.
 S 015-016
 (6)  Open the fan cowl panels (AMM 71-11-02/201).
 S 015-182
 (7)  Open the right hand thrust reverser half (AMM 78-31-00/201).
 S 865-067
 (8)  Set the start levers to the IDLE position.
 (a)  Make sure the engine 1 and engine 2 FUEL VALVE CLOSED lights on
 the P5 panel come on bright while the valves are in transit,
 and then each go off to indicate the valves are fully open.
 S 865-068
 (9)  Set the engine 1 and engine 2 bleed air switches in the ON position.
 (a)  Make sure the bleed air regulator solenoids for engine 1 and
 engine 2 open.
 NOTE:____ You can hear or feel the solenoid click.

 (b)  
Make sure the hydraulic system A and B fluid shutoff valves are open.

 (c)  
Make sure the low pressure lights for the engine hydraulics come on.


 S 865-071
 (10)
 Push the ERASE button on the M238 annunciator panel in the P6 well to set all lights.

 S 865-072

 (11)
 Push the override button behind the fire switch handle for engine 1 and pull the handle.

 S 865-073

 (12)
 Set the S2 switch on the M400 module to the A position.

 (a)  
Make sure the DC voltmeter shows zero volts.

 (b)  
Make sure the GEN 1 LV light on the M238 panel in the P6 well comes on.

 


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(107)