C. Prepare to do the Operational Test
S 865-002
(1)
Supply electrical power (Ref 24-22-00/201).
S 865-003
(2)
Make sure these circuit breakers are closed:
(a) P6 Load Control Center - Right
1) MASTER WARN & CONTROL
2) ENG NO. 1
3) ENG NO. 2
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-11-00
ALL ú ú 02A Page 501 ú Nov 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
4) AIRPLANES WITH KIDDE -98 FIRE DETECTOR UNITS;
APU 5) ANNUNCIATOR NO. 1 6) ANNUNCIATOR BAT 7) AIR/GND RELAY & LTS 8) INDICATOR MASTER DIM BUS BAT 9) INDICATOR MASTER DIM BUS NO. 1 DC 10) INDICATOR MASTER DIM BUS NO. 2 DC 11) INDICATOR SECT 1 thru 6 12) DIM & TEST
S 865-004
(3) Open these circuit breakers:
(a) P6 Load Control Center - Right
1) OVHT WHL WELL WING BDY
S 865-005
(4) Set the two OVHT DET switches on the P8-1 panel to the NORMAL position.
D. Procedure
S 865-006
(1) Open the FIRE PROTECTION DETECTION ENG 2 circuit breaker on the P6-2 panel.
(a) Make sure the FAULT light on the P8-1 panel comes on.
S 865-007
(2) Push and hold the TEST switch on the P8-1 panel in the OVHT/FIRE position.
(a)
Make sure these lights on the P8-1 panel come on: 1) the ENG 1 OVERHEAT light 2) all of the lights in the engine-1 fire switch 3) all of the lights in the APU fire switch.
(b)
Make sure these lights on the P7 panel come on: 1) AIRPLANES WITH OTHER THAN -98 FIRE DETECTION UNIT;
the two FIRE WARN lights
2) the two MASTER CAUTION lights
3) the OVHT/DET annunciator.
(c)
AIRPLANES WITH OTHER THAN -98 FIRE DETECTION UNIT; make sure that you hear the alarm bell in the control cabin.
S 755-008
(3) Release the TEST switch on the P8-1 panel.
(a) Make sure these lights on the P8-1 panel go off: 1) the ENG 1 OVERHEAT light 2) all of the lights in the engine-1 fire switch
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-11-00
ALL ú ú 04A Page 502 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
3) all of the lights in the APU fire switch.
(b)
Make sure these lights on the P7 panel go off: 1) AIRPLANES WITH OTHER THAN -98 FIRE DETECTION UNIT;
the two FIRE WARN lights
2) the two MASTER CAUTION lights
3) the OVHT/DET annunciator.
(c)
AIRPLANES WITH OTHER THAN -98 FIRE DETECTION UNIT; make sure that you do not hear the alarm bell in the control cabin.
S 865-009
(4) Close the FIRE PROTECTION DETECTION ENG 2 circuit breaker on the P6-2 panel.
(a) Make sure the FAULT light on the P8-1 panel goes off.
S 865-010
(5) Open the FIRE PROTECTION DETECTION ENG 1 circuit breaker on the P6-2 panel.
(a) Make sure the FAULT light on the P8-1 panel comes on.
S 865-011
(6) Set and hold the TEST switch on the P8-1 panel to the OVHT/FIRE position.
(a)
Make sure that these lights on the P8-1 panel come on: 1) the ENG 2 OVERHEAT light 2) all of the lights in the engine-2 fire switch 3) all of the lights in the APU fire switch.
(b)
Make sure these lights on the P7 panel come on: 1) AIRPLANES WITH OTHER THAN -98 FIRE DETECTION UNIT;
the two FIRE WARN lights
2) the two MASTER CAUTION lights
3) the OVHT/DET annunciator.
(c)
AIRPLANES WITH OTHER THAN -98 FIRE DETECTION UNIT; make sure that you hear the alarm bell in the control cabin.
S 865-012
(7) Release the TEST switch on the P8-1 panel.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(15)