• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-01 19:09来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

2.  Equipment and Materials
A.  Ohmmeter incapable of supplying more than 35 milliamperes.
_______ CURRENT FLOW EXCEEDING 35 MILLIAMPERES MAY DETONATE THE BOTTLE
WARNING:
DISCHARGE SQUIB.

3.  Trouble Charts
With all IND LIGHTS, and SEC 5 circuit breakers on P6-3 closed. 

APU BOTTLE DISCH LIGHT IS ON - Pressure is low. Replace bottle. 


EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-22-00
 ALL  ú
 ú  02  Page 101
 ú  Mar 15/92 

BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 APU FIRE EXTINGUISHING SYSTEM - ADJUSTMENT/TEST
_______________________________________________
 1.  General_______
 A.  This subject has 3 tasks. The first task is an operational test of the fire extinguishing system on the APU.
 B.  The second task is a system test. The test makes a check of the switch circuits between the P8 panel, the P28 panel and the squib connector.
 C.  The third task is a leakage test of the tubing used in the fire extinguisher system on the APU.
 TASK 26-22-00-715-001
 2.  Operational Test - APU Fire Extinguisher System_______________________________________________
 A.  References
 (1)  AMM 24-22-00/201, Manual Control
 B.  Access
 (1)  Location Zone
 (a)  
703 APU Compartment

 (b)  
101, 102 Control Cabin


 C.  Procedure
 S 865-002
 (1)  
Supply electrical power. (AMM 24-22-00/201)

 S 865-003

 (2)  
Open the APU access door and the 3701 access door.

 S 215-004

 (3)  
Make sure these circuit breakers are closed:

 (a)  
EXTINGUISHER BOTTLES APU on the P6-2 panel

 (b)  
All (3) IND LIGHTS on the P6-3 panel

 (c)  
SEC 5 on the P6-3 panel.

 


 S 755-005
 (4)  Do a Test of the APU Squib Circuit.
 (a)  
Make sure all the lights on the P8-1 panel are OFF.

 (b)  
Move the EXT TEST switch on the P8-1 panel to position 1 and hold it.

 (c)  
Make sure the APU light (green) on the P8-1 panel goes on.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-22-00
 ALL  ú ú 04 Page 501 ú Mar 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-079
 (5)  
Release the EXT TEST switch.

 S 755-082

 (6)  
Make sure all the lights on the P8-1 panel go off.

 (a)  
Move the EXT TEST switch to position 2 and hold it.

 (b)  
Make sure the APU light (green) on the P8-1 panel goes on.

 


 S 865-080
 (7)  
Release the EXT TEST switch.

 S 755-081

 (8)  
Make sure all the lights on the P8-1 panel go off.

 S 755-006

 (9)  
Do a Test of the APU Pressure Switch Circuit

 (a)  
Disconnect the D1176 connector found behind the 3701 access door.

 (b)  
Install a jumper across pins 1 and 2 of the D1176 connector.

 (c)  
Make sure the APU BOTTLE DISCHARGED light (amber) on the P8-1 panel comes on.

 (d)  
Remove the jumper from pins 1 and 2 of the D1176 connector.

 (e)  
Connect the D1176 connector to the bottle pressure switch on the APU.

 


 D. Put the airplane to its usual condition.
 S 865-008
 (1)  
Remove electrical power if it is not necessary (AMM 24-22-00/201).

 S 865-009

 (2)  
Close the 3701 access door and the APU access door.


 TASK 26-22-00-735-058
 3.  System Test - APU Fire Extinguisher System__________________________________________
 A. Equipment
 (1)  
F80229-15, Test Box, Fire Extinguisher System
 
中国航空网 www.aero.cn