 S 014-003
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH LOWER CARGO ú

 26-23-02
 FIRE EXTINGUISHING SYSTEM  ú ú 01 Page 401 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL 
HEAD DISCHARGE GLAND NUT 
COMPARTMENT MIX BAY  DISCHARGE PORT 

LUG ASSY-GND
2. LOCKWIRE 
CARGO FIRE  1. DISCHARGE
EXTINGUISHER  CARTRIDGE PROTECTIVE 
BOTTLE  (SQUIB)  COVER 
SEE  A  (EXAMPLE) 

CARGO FIRE 
EXTINGUISHER 
BOTTLE (REF) 

FORWARD
SQUIB

SEE B
AFT SQUIB  ELECTRICAL CONNECTOR
SEE B (2 LOCATIONS)FWD
CARGO FIRE EXTINGUISHER BOTTLE
A

Cargo Compartment Fire Extinguisher Bottle Squib Installation Figure 401
G87055
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH LOWER CARGO ú

 26-23-02
 FIRE EXTINGUISHING SYSTEM  ú ú 01 Page 402 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 S 864-006
 WARNING: DO NOT TOUCH THE SQUIB BEFORE YOU DO THE PROCEDURES FOR DEVICES
_______ THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE THE FIRE BOTTLE TO RELEASE ITS CONTENTS SUDDENLY AND CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (5)  Before you touch the squibs, do the procedure for devices that are sensitive to electrostatic discharge (AMM 20-40-12/201).
 E. Remove the Squib
 S 034-007
 (1) Disconnect the electrical connectors from the applicable squib.
 (a)  
Disconnect the FWD Squib (M2249) connector, D12794.

 (b)  
Disconnect the AFT Squib (M2250) connector, D12796.


 S 434-008
 WARNING:_______PUT A PROTECTIVE COVER ON THE FIRE BOTTLE SQUIB. IF YOU DO NOT PUT A PROTECTIVE COVER ON THE FIRE BOTTLE SQUIB, THE FIRE BOTTLE CAN RELEASE ITS CONTENTS SUDDENLY AND CAUSE INJURY TO PERSONS.
 (2)  
Put a protective cover on the squib (1).

 S 034-009

 (3)  
Remove the lockwire (2) from the squib (1).

 S 024-010

 (4)  
Remove the squib (1) from the discharge head.


 TASK 26-23-02-404-011
 3.  Install the Cargo Fire Extinguishing Bottle Squib (Fig. 401)_________________________________________________
 A. Equipment
 (1)  Voltmeter - with a 10K ohm or greater resistance
 B. References
 (1)  
20-40-12/201, Electrostatic Sensitive Devices - Maintenance Practices

 (2)  
24-22-00/201, Manual Control


 C. Access
 (1)  
Location Zones
 210 Air Conditioning Distribution Bay


 (2)  
Access Panels
 4404R, Forward Cargo Compartment Door

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH LOWER CARGO ú

 26-23-02
 FIRE EXTINGUISHING SYSTEM  ú ú 01 Page 403 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 D. Prepare for the Installation
 S 864-012
 (1)  Open this circuit breaker on the circuit breaker panel P6 or P18, and attach DO-NOT-CLOSE tags:
 (a)  LWR CARGO FIRE EXT 1
 S 014-013
 (2)  
Open the forward cargo door, 4404R.

 S 014-014

 (3)  
Remove the lining at the aft end of the forward cargo compartment to get access to the mix manifold bay.

 S 014-015

 (4)  
If it is necessary, remove the air conditioning duct that is in front of the fire extinguishing bottle.


 E. Install the Squib
 S 424-016
 (1)  Do these steps to install the squib.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(145)