 Put the EXT TEST switch on the P8-1 panel to position 1 and hold it.

 S 752-034

 (22)
 Make sure only these lights on the P8-1 panel come on:

 (a)
R (green)

 (b)
L (green)

 (c)
APU (green)

 


 S 712-035
 (23) Release the EXT TEST switch.
 (a) Make sure all the lights on the P8-1 panel go off.
 S 712-036
 (24)
 Put the EXT TEST switch to position 2 and hold it.

 S 752-037

 (25)
 Make sure only these lights on the P8-1 panel come on:

 (a)
R (green)

 (b)
L (green)

 (c)
APU (green)

 


 S 712-038
 (26)
 Release the EXT TEST switch.

 (a) Make sure all the lights on the P8-1 panel go off.

 (27)
 Remove electrical power if it is not necessary (AMM 24-22-00/201).


 S 862-039
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-31
 ALL  ú ú 05 Page 206 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 ENGINE AND APU FIRE CONTROL MODULE - REMOVAL/INSTALLATION
_________________________________________________________
 1.  General_______
 A. The engine and APU fire control module is in the pilot's control stand.
 TASK 26-21-51-004-001
 2.  Remove the Fire Control Module______________________________
 A. Access
 (1)  Location Zone
 101, 102 Control Cabin

 B. Procedure
 S 864-002
 (1)  Open these circuit breakers on the main power distribution panel, P6:
 -
EXTINGUISHER BOTTLES LEFT

 -
EXTINGUISHER BOTTLES RIGHT

 -
EXTINGUISHER BOTTLE LEFT

 -
EXTINGUISHER BOTTLE RIGHT


 -APU FIRE EXT BOTTLES
 -
ENG 1 R IGN

 -
ENG 1 L IGN

 -
ENG 2 R IGN

 -
ENG 2 L IGN


 S 034-003
 (2)  
Loosen the module mounting screws.

 (3)  
Move the engine start lever to the RUN position.

 (4)  
Pull the module.

 (5)  
Disconnect the electrical connectors.

 (6)  
Remove the module.


 S 984-014
 S 014-004
 S 034-005
 S 024-006
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-51
 ALL  ú ú 01 Page 401 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 S 984-015
 (7)  Move the engine start lever to the CUTOFF position.
 (a)  Keep the lightplate until you can use it when you install the panel.
 TASK 26-21-51-404-007
 3. Install the Fire Control Panel
______________________________
 A. References
 (1)  26-21-51/501, Engine and APU Fire Control Module - Adjustment/Test 24-22-00/201, Electrical Power - Control
 B. Access
 (1)  Location Zone
 101, 102 Control Cabin

 C. Procedure
 S 424-008
 (1)  
Install the lightplate.

 S 434-009

 (2)  
Connect the electrical connectors to the module.

 S 984-016

 (3)  
Move the engine start lever to the RUN position.

 S 424-010

 (4)  
Install the module.

 S 984-017

 (5)  
Move the engine start lever to the CUTOFF position.


 (a)  Tighten the mounting screws.
 S 864-011
 (6)  Close these circuit breakers on the P6 panel:
 -
EXTINGUISHER BOTTLES LEFT

 -
EXTINGUISHER BOTTLES RIGHT

 -
EXTINGUISHER BOTTLE LEFT

 -
EXTINGUISHER BOTTLE RIGHT


 -APU FIRE EXT BOTTLES
 -
ENG 1 R IGN

 -
ENG 1 L IGN
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(103)