737-300/400/500MAINTENANCE MANUAL
 S 712-018
 (5)  Put the EXT TEST switch on the P8-1 panel to position 1 and hold it. (a) Make sure all the lights on the P8-1 panel stay off.
 S 712-019
 (6)  Put the EXT TEST switch to position 2 and hold it. (a) Make sure all the lights on the P8-1 panel stay off.
 S 862-020
 (7)  Open these circuit breakers and attach DO-NOT-CLOSE tags: (a) P6 Load Control Center Panel 1) EXTINGUISHER BOTTLES RIGHT 2) EXTINGUISHER BOTTLES LEFT 3) EXTINGUISHER BOTTLE RIGHT 4) EXTINGUISHER BOTTLE LEFT
 S 862-041
 (8)  Remove the shunt plugs from these engine squibs: (a) Squib 1 (forward) on the L (forward) fire extinguisher bottle. (b) Squib 2 (aft) on the R (aft) fire extinguisher bottle.
 S 712-021

 WARNING: DO NOT INSTALL ELECTRICAL CONNECTORS TO THE SQUIBS IF THERE IS
_______ VOLTAGE AT THE CONNECTOR PINS. INJURY TO PERSONS CAN OCCUR IF THE SQUIB IS ACCIDENTALLY FIRED.
 (9)  Connect these electrical connectors:
 (a)  
D582 to squib 1 (forward) on the L (forward) fire extinguisher bottle.

 (b)  
D1324 to squib 2 (aft) on the R (aft) fire extinguisher bottle.


 S 862-022
 (10) Close these circuit breakers:
 (a)  P6 Load Control Center Panel 1) EXTINGUISHER BOTTLES RIGHT 2) EXTINGUISHER BOTTLES LEFT 3) EXTINGUISHER BOTTLE RIGHT 4) EXTINGUISHER BOTTLE LEFT 5) EXTINGUISHER BOTTLE APU
 S 712-023
 (11)
 Put the EXT TEST switch on the P8-1 panel to position 1 and hold it.

 S 752-024

 (12)
 Make sure only these lights on the P8-1 panel come on:

 (a)  
L (green)

 (b)  
APU (green)

 


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-31
 ALL  ú ú 02 Page 204 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 712-025
 (13) Release the EXT TEST switch.
 (a)  Make sure all the lights on the P8-1 panel go off.
 S 712-026
 (14)
 Put the EXT TEST switch to position 2 and hold it.

 S 752-027

 (15)
 Make sure only these lights on the P8-1 panel come on:

 (a)  
R (green)

 (b)  
APU (green)

 


 S 712-028
 (16) Release the EXT TEST switch.
 (a)  Make sure all the lights on the P8-1 panel go off.
 S 862-029
 (17) Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  
P6 Load Control Center Panel

 (b)  
EXTINGUISHER BOTTLES RIGHT

 (c)  
EXTINGUISHER BOTTLES LEFT

 (d)  
EXTINGUISHER BOTTLE RIGHT

 (e)  
EXTINGUISHER BOTTLE LEFT


 S 862-030
 (18) Remove the shunt plugs from the these engine squibs:
 (a)  
Squib 1 (forward) on R (aft) fire extinguisher bottle

 (b)  
Squib 2 (aft) on L (forward) fire extinguisher bottle


 S 712-031
 WARNING: DO NOT INSTALL ELECTRICAL CONNECTORS TO THE SQUIBS IF THERE IS
_______ VOLTAGE AT THE CONNECTOR PINS. INJURY TO PERSONS CAN OCCUR IF THE SQUIB IS ACCIDENTALLY FIRED.
 (19) Connect these electrical connectors:
 (a)  
D584 to squib 1 (forward) on the R (aft) fire extinguisher bottle.

 (b)  
D1322 to squib 2 (aft) on the L (forward) fire extinguisher bottle.


 S 862-032
 (20) Close these circuit breakers:
 (a)  
P6 Load Control Center Panel

 (b)  
EXTINGUISHER BOTTLES RIGHT

 (c)  
EXTINGUISHER BOTTLES LEFT

 (d)  
EXTINGUISHER BOTTLE RIGHT

 (e)  
EXTINGUISHER BOTTLE LEFT


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-21-31
 ALL  ú ú 03 Page 205 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.