MINIMUM INSULATION RESISTANCE (MEGOHMS)
TABLE II (DETECTORS WITH TERMINAL LUGS)
Engine OVHT and Fire Detection System
Figure 102A
F90208
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-11-00
ALL ú
ú 01 Page 105
ú Jul 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
PROCEDURE
4. Restore System to Normal
A. Close the following circuit breakers:
(1)
FIRE PROTECTION DETECTION APU on panel P6-2.
(2)
OVHT WHL WELL WNG BDY on panel P6-2.
B. Remove electrical power if no longer required (Ref 24-22-00 MP).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-11-00
ALL ú
ú 01 Page 106
ú Jul 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
ENGINE FIRE DETECTION SYSTEM - ADJUSTMENT/TEST
______________________________________________
1. General_______
A. The engine fire detection system monitors the engine nacelle temperature for fire and overheat conditions. Dual-loop fire/overheat detectors are in each engine area.
B. The system uses power from the 28-volt dc battery bus. The circuit breakers are on the P6 panel.
C. The engine fire detection system components are: the fire detectors, the engine and APU fire detection accessory unit, and the engine and APU fire control panel.
D. There are two tasks in this section:
(1)
Operational Test of the Engine Fire Detection System
(a) The operational test is done in a minimum of time, and uses equipment installed on the airplane to make sure that the system will operate correctly.
(2)
System Test of the Engine Fire Detection System.
(a) The system test is a full check of the engine fire-detection system.
TASK 26-11-00-715-001
2. Do the Operational Test of the Engine Fire Detection System___________________________________________________________
A. References