(b)
Hold the element so it does not bend.
(c)
Put the element fitting into the bracket on the heat shield, then clamp sensing element into position.
(3)
Install the jamnuts.
S 434-100
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-15-14
ALL ú ú 09 Page 408 ú Nov 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 034-101
CAUTION:_______ ONLY USE ISOPROPYL OR METHYL ALCOHOL OR ACETONE TO CLEAN
CONNECTORS. DO NOT USE OTHER CLEANING SOLVENTS. COMMERCIALLY
AVAILABLE CONTACT CLEANERS MAY CONTAIN CHLORIDES WHICH PROMOTE
CORROSION IN SEALED AREAS, AND SHOULD NOT BE USED.
(4)
Remove the protective caps from the electrical connectors and make sure the detector and the connectors are clean. If contamination is found refer to the wiring diagram manual (AMM 20-30-31/201) to clean them.
S 644-102
(5)
Apply a very light coat of DC-4 silicone grease to the copper sealing gasket on the plug connector.
NOTE: Do not get grease in the connector, on connector pins,
____ or on the contacts.
S 434-096
(6)
Carefully connect the electrical connectors.
S 434-097
(7)
Tighten the electrical connectors to a torque of 50-70 pound-inches.
S 434-098
(8)
Lockwire the element end fittings, jamnuts and electrical connectors together.
S 424-099
(9)
Tape the loose end of the sensing element cable to the heat shield and muffler assembly.
S 414-055
(10)
Install the APU aft fairing (AMM 49-81-31/401).
S 434-103
CAUTION:_______ONLY USE METHYL ALCOHOL OR ACETONE TO CLEAN CONNECTORS. DO NOT USE OTHER CLEANING SOLVENTS. COMMERCIALLY AVAILABLE CONTACT CLEANERS MAY CONTAIN CHLORIDES WHICH PROMOTE CORROSION IN SEALED AREAS, AND SHOULD NOT BE USED.
(11) Remove the protective caps from the electrical connectors and make sure the detector and the connectors are clean. If contamination is found refer to the wiring diagram manual (AMM 20-30-31/201) to clean them.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-15-14
ALL ú ú 05 Page 409 ú Nov 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 644-090
(12) Apply a very light coat of DC-4 silicone grease to the copper sealing gasket on the plug connector.
NOTE: Do not get grease in the connector, on connector pins or
____
the contacts.
S 424-091
(13)
Carefully connect the electrical connectors.
S 434-092
(14)
Tighten the electrical connectors to 50-70 pound-inches.
S 424-093
(15)
Connect the cable leading to overheat sensing element.
S 434-094
(16)
Clamp the cable in place.
S 734-056
(17)
Do the APU fire detection system test (AMM 26-15-00/501).
S 414-057
(18)
Install the drip pan.
S 434-058
(19)
Lockwire the end fittings, jamnuts and electrical connectors together.
S 414-069
(20)
Install the APU aft fairing (AMM 49-81-31/401).
S 734-070
(21)
Do the APU fire detection system test (AMM 26-15-00/501).
S 414-071
(22)
Install the drip pan.
E. Return Airplane to Normal Configuration
S 434-059
(1)
Install the APU lower shroud.
(2)
Remove the door support rods.
(3)
Close the APU access door.
S 034-060
S 414-061
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(45)