S 216-005
(4)
Make sure the lock-pin or lock-wire is correctly installed on the handle.
S 216-006
(5)
Examine the pressure gage and make sure the extinguisher has the correct pressure.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH HALON FIRE EXTINGUISHERS ú
26-26-01
ú ú 01 Page 601 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(6) S 216-007Make sure there is no physical damage to the extinguisher.
(7) S 216-008Make sure the weight of the extinguisher is not less than the weight shown on the extinguisher nameplate.
(8) S 216-009If there are other manufacturer inspection or maintenance procedures that show on the extinguisher, do these procedures.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH HALON FIRE EXTINGUISHERS ú
26-26-01
ú ú 01 Page 602 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
HANDLE
LOCK-PIN
GAGE
QUICK-RELEASE STRAP
HALON FIRE EXTINGUISHER
Halon Fire Extinguisher - Inspection/Check
Figure 601
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH HALON FIRE EXTINGUISHERS ú
26-26-01
ú ú 01 Page 603 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
G91385
A
737-300/400/500MAINTENANCE MANUAL
WATER-TYPE FIRE EXTINGUISHERS - INSPECTION/CHECK
________________________________________________
1. General_______
A. This procedure has a task to inspect the portable water fire
extinguishers.
B. The portable fire extinguishers are installed in several general locations in the passenger compartment and flight compartment. If the extinguisher is not easy to see, the location will be indentified with a placard. The extinguishers are usually installed in one or more of these areas: galley or lavatory stowage areas, closets, doghouses, or near attendant seats.
C. To service or recharge the fire extinguisher, refer to the applicable vendor manuals.
TASK 26-26-02-216-001
2. Water Fire Extinguishers Inspection/Check_________________________________________
A. References
(1) IPC 26-23-00
B. Access
(1) Location Zones
107 Cabin
108 Cabin
C. Procedure
S 216-002
(1)
Make sure the instruction decal and the nameplate are in good condition.
S 216-003
(2)
Make sure the mounting bracket is attached correctly to the airplane.
S 216-004
(3)
Make sure the extinguisher is installed tightly to the mounting bracket.
S 216-005
(4)
Make sure the lock-pin or lock-wire is correctly installed on the handle.
S 216-006
(5)
Examine the pressurized cartridge and make sure it is correctly installed and in good condition.
(6)
Make sure there is no physical damage to the extinguisher.
S 216-007
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH WATER-TYPE FIRE ú
26-26-02
EXTINGUISHERS ú ú 01 Page 601 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
FIRE EXTINGUISHER (EXAMPLE)
Water-Type Fire Extinguisher - Inspection/Check
Figure 601
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH WATER-TYPE FIRE ú 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300 400 500 AMM 飞机维护手册 防火 FIRE PROTECTION(150)