To access the aft nozzles, open the forward cargo door.


 C.  Remove the Nozzles.
 S 034-006
 (1)  Remove the discharge nozzles from the discharge tubes.
 (a)  
Remove the two screws securing the discharge nozzle and spacer to the pan cover assembly.

 (b)  
Loosen the nut and remove the discharge nozzle and spacer.


 TASK 26-23-03-404-012
 3.  Install the Cargo Fire Suppression Nozzles (Fig. 401)__________________________________________
 A.  Access
 (1)  Location Zones
 208 Forward Cargo Compartment
 218 Aft Cargo Compartment

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-23-03
 ALL  ú ú 01 Page 401 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

737-300/400/500
MAINTENANCE MANUAL

AFT CARGO 
COMPARTMENT 
MIX BAY 
COMPARTMENT 
FORWARD 
CARGO 
COMPARTMENT 
DISCHARGE 
NOZZLE 
SEE  A 

NOZZLE DISCHARGE 
SEE  A  NUT  TUBE DISCHARGE 

CARGO CEILING (REF)
2. SPACER
1. DISCHARGE NOZZLE
3. SCREW (2 LOCATIONS)
DISCHARGE NOZZLE (EXAMPLE)
A
Cargo Bay Fire Extinguishing Nozzle Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-23-03
 ALL  ú ú 01 Page 402 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
M29088
A
737-300/400/500MAINTENANCE MANUAL
 B. Prepare for the Installation
 S 864-013
 (1)  Open this circuit breaker and attach a DO-NOT-CLOSE tag:
 (a)  Circuit breaker panel P6 or P18
 1) LWR CARGO FIRE EXT BTL 1

 S 014-014
 (2)  
To access the forward nozzles, open the forward cargo door.

 S 014-015

 (3)  
To access the aft nozzles, open the forward cargo door.


 C. Install the Nozzles.
 S 424-016
 (1)  Install the discharge nozzles on the discharge tubes.
 (a)  Install the discharge nozzle and spacer on the discharge tube and hand tighten.
 NOTE: Make sure the holes in the discharge nozzle and spacer
____ line up with those in the pan cover assembly.
 (b)  
Tighten the nut 45-55 foot-pounds (61-75 Nm), and install lockwire.

 (c)  
Secure the discharge nozzle with the screws.

 (d)  
Install the cargo ceiling.


 D. Put the Airplane Back to Its Usual Condition
 S 864-023
 (1)  
Remove the DO-NOT-CLOSE tag and close this circuit breaker:

 (a)  Circuit Breaker Panel, P6 or P18
 1) LWR CARGO FIRE EXT BTL 1


 (2)  
Close the cargo doors.


 S 414-027
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-23-03
 ALL  ú ú 01 Page 403 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 LAVATORY FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION
______________________________________________________________
 1.  General_______
 A.  The lavatory fire extinguishing system provides fire extinguishing for the lavatory waste compartment by flooding the compartment with inert gas.
 B.  The fire extinguishing agent is non-corrosive. There are no special inspection or cleaning procedures required if the agent is discharged when there is no fire in the lavatory.
 C.  The system is a heat-activated extinguisher bottle and a temperature indicator.
 2.  Fire Extinguisher Bottle (Fig. 1)________________________
 A.  The bottle is a steel container, about 2.5 inches in diameter with volume of approximately 10 cubic inches, with discharge tubes, fusible tips, and mounting bracket. The container is filled with freon.
 