 (e)  
Release the TEST switch.

 (f)  
Make sure the indications are as follows:
 1) The WHEEL WELL light goes off.

 

 S 715-026
 (3)  Do the test of the left FIRE WARN switch for the wheel well overheat detection system.
 (a)  
Move the TEST switch on the P8-1 panel to the OVHT/FIRE position and hold.

 (b)  
Make sure the indications are as follows:
 1) The two FIRE WARN lights come on.
 2) The WHEEL WELL light comes on.
 3) The alarm bell operates.


 (c)  
Push the left FIRE WARN light.

 (d)  
Make sure that the indications are as follows:
 1) The alarm bell makes no sound.
 2) The two FIRE WARN lights go off.
 3) The WHEEL WELL light stays on.


 (e)  
Release the TEST switch.

 (f)  
Make sure that the indications are as follows:
 1) The WHEEL WELL light goes off.

 

 S 715-027
 (4)  Do the test of the right FIRE WARN switch for the wheel well overheat detection system.
 (a)  
Move the TEST switch on the P8-1 panel to the OVHT/FIRE position and hold.

 (b)  
Make sure that the indications are as follows:
 1) The two FIRE WARN lights come on.
 2) The WHEEL WELL light comes on.
 3) The alarm bell operates.


 (c)  
Push the right FIRE WARN light.

 (d)  
Make sure that the indications are as follows:
 1) The alarm bell makes no sound.

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-17-00
 ALL  ú ú 02 Page 502 ú Nov 15/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 2) The two FIRE WARN lights go off. 3) The WHEEL WELL light stays on.
 (e)  
Release the TEST switch.

 (f)  
Make sure that the indications are as follows: 1) The WHEEL WELL light goes off.


 E. Put the Airplane Back to its Usual Condition
 S 865-022
 (1)  Close these circuit breakers:
 (a)  P6 Load Control Center - Right 1) FIRE PROTECTION DETECTION ENG NO. 1 2) FIRE PROTECTION DETECTION ENG NO. 2 3) FIRE PROTECTION DETECTION APU
 S 865-023
 (2)  Remove electrical power if it is no longer necessary (AMM 24-22-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-17-00
 ALL  ú ú 01 Page 503 ú Nov 15/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 WHEEL WELL OVERHEAT DETECTION SENSING ELEMENT - REMOVAL/INSTALLATION
____________________________________________________________________
 1.  General_______
 A.  This procedure contains two tasks. The first task removes the overheat detection sensor element in the wheel well. The second task installs the sensor element.
 B.  The minimum bend radius for the sensor element is one inch. If it is possible, do not bend the element in a radius less than three inches. Keep the element straight for at least one inch around all connectors and mounting clips. Near the connectors keep the element straight for as long as possible.
 TASK 26-17-11-004-001
 2.  Remove the Sensing Element (Fig. 401)__________________________
 A.  Access
 (1)  Location Zones
 216/217 Left/Right Main Wheel Well
 101/102 Control Cabin

 B.  Procedure
 S 864-002
 (1)  Open this circuit breaker:
 (a)  P6 Load Control Center Panel
 1) OVHT WHL WELL WING BDY

 S 034-003
 (2)  Disconnect the electrical connectors at each end of the sensor element.
 (a)  Put caps or tape on the open ends of the electrical connectors.
 S 034-004
 (3)  Start at one end and remove the sensor element from each mounting clip.
 NOTE: Carefully hold the sensor element so it does not bend.