Case 2 DC BAT is displayed in amber when the voltage value from the BCL1 and from the BCL2 are both below 25V. Case 3 DC BAT is replaced by amber XX when both voltages from the BCL1 and the BCL2 are not available.
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 004)
**ON A/C ALL
G. Item 7 - Battery 2 charge/discharge operation
Refer to the para. ELEC Page links below.
H. Item 8 - Battery 2 operation
Refer to item 3 as the same principles apply. Only the title is different: replace BAT 1 by BAT 2.
J. Item 9 - DC Busbar 2 indication
Refer to item 2 as the same principles apply. Only the bus title is different: replace DC 1 by DC 2.
1EFF : ALL 1 31-67-24Page 11 1 1 Aug 01/05 1 1 1CES 1
K. Item 10 - Emergency generator operation
The title EMER GEN (item A)
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 006)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 007)
**ON A/C ALL
is displayed in white.
It is displayed in amber when the voltage or the frequency is itself
displayed in amber.
The voltage (item B)
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 006)
**ON A/C ALL
is normally displayed in green, when in the range 110V - 120V. It is
displayed in amber when outside this range. The display can vary from 0
to 999V.
The frequency (item C)
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 006)
**ON A/C ALL
is displayed in green when in the range 390Hz - 410Hz. It is displayed in amber when outside this range. The display can vary from 0 to 999Hz.
1EFF : ALL 1 31-67-24Page 12 1 1 Aug 01/05 1 1 1CES 1
ELEC Page - Display of the Parameters: EMERGENCY GENERATOR, ESSENTIAL TR, AC
GENERATORS
Figure 006
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-24 Page 13
1 1 Aug 01/05
1 1
1CES 1
ELEC Page - Display of the Parameters: EMERGENCY GENERATOR, ESSENTIAL TR, AC
GENERATORS
Figure 007
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 Page 1431-67-24
1201-299, 301-302, 1 May 01/05
1 1
1CES 1
L. Item 11 - Transformer rectifier 2 operation Refer to item 1 as the same principle apply. Only replace the title TR 1 by TR 2.
M. Item 12 - Emergency Generator line contactor
Refer to the para. ELEC Page links below.
N. Item 13 - AC Busbar 2 indication AC 2 is normally displayed in green (case 1). It is displayed in amber when there is no voltage on the barbus as transmitted to the SDAC by the relay 15XC (case 2).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
The rectangle is empty when the information is not transmitted correctly by the SDAC.
R **ON A/C 106-149, 303-399, 401-499,
The title AC2 is replaced by amber XX when the information is not transmitted correctly by the SDAC (case 3).
**ON A/C ALL
P. Item 14 - Generator 2 operation
GEN 2 (item A)
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 006)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 007)
1EFF : ALL 1 31-67-24Page 15 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 106-149, 303-399, 401-499,
is normally displayed in white.
The GEN title is displayed in amber when
-
the generator pushbutton is set to OFF
-
the generator frequency is outside the range 390 Hz/410 Hz
-
the generator voltage is outside the range 110V/120V
-a generator overload occurs
(provided these informations are transmitted by the SDAC as valid)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
is normally displayed in white. It is displayed in amber when the engine is not running, as transmitted by the engine bus.
**ON A/C ALL
The GEN LOAD (item B) is displayed in green. It is displayed in amber in case of an overload transmitted by the SDAC. The display can vary from 0 to 999%. The voltage (item C) is displayed in green when inside the range: 110V -120V, and displayed in amber when outside this range. The display can vary from 0 to 999V.
R **ON A/C 106-149, 303-399, 401-499,
Item (B) or (C) are replaced by amber XX when the related value is transmitted not valid by the SDAC.