**ON A/C ALL
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 006)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 007)
**ON A/C ALL
(7)
A green arc (case 1) is displayed on the hottest wheel when the related temperature is higher than 100.C and there is no overheat on the brake.
(8)
The arc is displayed in amber (case 2) when there is an overheat.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(9) No arc is displayed when the temperature is lower than 100.C.
R **ON A/C 106-149, 303-399, 401-499,
(9) The same arc is displayed in grey (case 3) when the related wheel is not the hottest wheel and in all other cases.
(10)
Item 13: L/G CTL Message
(see above)
(11)
Item 14: Hydraulic status *** NEW MSG DISPLAY OPTION ACTIVATED *** The hydraulic supply indications are displayed at the same time as the message N/W STEERING, or the message NORM BRK, or the message ALTN BRK Y refer to the YELLOW hydraulic status, while G refer to the GREEN hydraulic status. The letter, normally displayed in green, is displayed in amber in case of low pressure. The hydraulic status is not displayed when not transmitted as valid by the SDAC.
1EFF : ALL 1 31-67-32Page 30 1 1 Aug 01/05 1 1 1CES 1
SYSTEM DISPLAY - OXY PAGE - DESCRIPTION AND OPERATION
_____________________________________________________
1. General
_______ The Oxygen information being displayed together with the DOOR PAGE, Please refer to the Chap. 316752.
1EFF : ALL 1 31-67-35Page 1 1 1 Feb 01/98 1 1 1CES 1 SYSTEM DISPLAY - BLEED PAGE - DESCRIPTION AND OPERATION
_______________________________________________________
1. "BLEED Page"
____________ The BLEED Page is described in the following figure with its 29 parameters as follows:
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 001)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 002)
**ON A/C ALL
Item 1: Cold air duct supply
Item 2: Emer RAM air valve
Items 3 and 29: Pack outlet temp
Items 4 and 28: Temperature control valve
Items 5 and 27: Pack compressor outlet temp
Item 6 and 26: Pack flow
Items 7 and 25: Pack flow control valve
Item 8 and 24: ANTI ICE indications
Items 9 and 23: Wing anti ice valve not closed
Items 10 and 22: ENG precooler inlet press
Items 11 and 21: ENG precooler outlet temperature
Items 12 and 20: ENG number
Items 13 and 19: ENG bleed valve
Items 14 and 18: ENG H.P bleed valve
1EFF : ALL 1 31-67-36Page 1 1 1 Aug 01/05 1 1 1CES 1
SD - BLEED Page: Display of the 29 Parameters
Figure 001
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-36Page 2 1 1 Aug 01/05 1 1 1CES 1
SD - BLEED Page: Display of the 29 Parameters
Figure 002
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-67-36Page 3 1201-299, 301-302, 1May 01/05 1 1 1CES 1
A. Cold air duct supply
(Item 1)
Indications of Bleed Users
The triangles indicate if the mixer unit is supplied by air from packs or ram air.
The triangles are amber if the two flow control valves and the RAM air
valve are fully closed (in flight).
The triangles are amber if the two flow control valves are fully closed
(on ground).
They are green in the other cases.
The same principle applies to the flow bar which links the pack to the
triangles. They are amber when the relevant pack flow control valve is
fully closed. They are green in the other cases.
B. Emer RAM air valve
(Item 2)
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 003)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 004)
**ON A/C ALL
(1) Case 1
The valve is normally green and closed.
1EFF : ALL 1 31-67-36Page 4 1 1 Aug 01/05 1 1 1CES 1
BLEED Page - Display of the Parameter: RAM AIR VALVE
Figure 003
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-36Page 5 1 1 Aug 01/05 1 1 1CES 1
BLEED Page - Display of the Parameter: RAM AIR VALVE
Figure 004