 Item 1: APU GEN operation Item 2: APU GEN line contactor Item 3: APU available Item 4: APU bleed valve Item 5: APU bleed operation Item 6: APU fuel LO press Item 7: APU air intake flap fully open Item 8: APU oil quantity Item 9: APU EGT Item 10: APU (N) The symbols related to these indications are described hereafter:
 1EFF : ALL 1 31-67-49Page 1 1 1 Aug 01/05 1 1 1CES 1


 SD - APU Page: Display of the 10 Parameters
 Figure 001

R 1EFF : 106-149, 303-399, 401-499, 1 31-67-49Page 2 1 1 Aug 01/05 1 1 1CES 1


 SD - APU Page: Display of the 10 Parameters
 Figure 002

R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-67-49Page 3 1201-299, 301-302, 1May 01/05 1 1 1CES 1


 A. APU Generator operation
 (Item 1)


R **ON A/C 106-149, 303-399, 401-499,
 (Ref. Fig. 003)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 (Ref. Fig. 004)
 **ON A/C ALL
 The main parameters of the generator operation are described in this rectangle.
 (1) Case 1 In this case the generator is not in standby and is not off.
 -
Item A The title APU GEN is normally displayed in white. It is displayed in amber: when the generator load below is amber, when the voltage is amber, when the frequency is amber.

 -
Item B Generator load The generator load is normally displayed in green. It is displayed in amber when there is a generator overload as transmitted by the SDAC. It is replaced by amber XX when the value is not available from the SDAC.

 -
Item C Generator voltage The generator voltage is normally displayed in green. It is displayed in amber when the value is outside the range 110V/120V as transmitted by the SDAC. It is replaced by amber XX when the value is not available from the SDAC.


 1EFF : ALL 1 31-67-49Page 4 1 1 Aug 01/05 1 1 1CES 1


 APU Page - Display of the Parameter: APU GENERATOR
 Figure 003

R 1EFF : 106-149, 303-399, 401-499, 1 31-67-49Page 5 1 1 Aug 01/05 1 1 1CES 1


 APU Page - Display of the Parameter: APU GENERATOR
 Figure 004

R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-67-49Page 6 1201-299, 301-302, 1May 01/05 1 1 1CES 1


 -Item D Generator frequency The generator voltage is normally displayed in green. It is displayed in amber when the value is outside the range 390Hz/410Hz as transmitted by the SDAC. It is replaced by amber XX when the value is not available from the SDAC.
 (2)
 Case 2 In this case the generator is off. The APU GEN P/B is off and the generator is not in the standby mode. The title APU GEN is amber and the OFF indication is white.

 (3)
 Case 3
 In this case the generator is in the standby mode.

 

 The APU GEN is in the standby mode when the APU/MASTER SW P/BSW is in OFF configuration (information from the SDAC) and the APU is not available (information from the Electronic Control Box (ECB) via the SDAC).
 The title APU GEN is white.
 B. APU GEN line contactor
 (item 2)

 The triangle is green when the APU GEN line contactor is closed as transmitted by the SDAC. It is not displayed in all other cases.
 C. APU available (Item 3) The green AVAIL message computed by the APU Electronic Control Box (ECB) is displayed
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 when the APU speed N (% RPM) is above 95%.

R **ON A/C 106-149, 303-399, 401-499,
 when the APU is considered available by the ECB, and transmitted as such to the DMC: APU AVAIL signal set to true.
 1EFF : ALL 1 31-67-49Page 7 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 Then, the APU is able to provide bleed air and/or electrical power. Nothing is displayed in the other cases (or when the status of the APU is not transmitted to the DMC).
 D. APU bleed valve
 (Item 4)


R **ON A/C 106-149, 303-399, 401-499,
 (Ref. Fig. 005)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 (Ref. Fig. 006)
 **ON A/C ALL
 (1)
 Case 1
 green and open when the valve is not fully closed


 (2)
 Case 2
 green and closed when the valve is fully cllosed


 (3)
 Case 3 amber and closed when the valve is fully closed but commanded ON, confirmed 10s (APU BLEED P/B selected ON).

 (4)
 Case 4 replaced by amber XX when the valve position is not available (when bleed air valve status information is not available or APU bleed pushbutton status is not available).


 E. APU bleed pressure
 (Item 5)


 