(2)
 Case 2: It becomes pulsing green when either the high or the low temperature advisory is reached.
 (3)
 Case 3: It turns amber when either the high or the low limit of the inner cell temperature is reached.
 (4)
 Case 4: The value displayed is replaced by amber XX, when no valid data are available.
R **ON A/C 106-149, 401-499,
 D. Item 3 - Left fuel transfer valve
 (Ref. Fig. 003)
 (1)
 Case 1: Valve closed No triangle is displayed when the valve is normally closed.
 (2)
 Case 2:
 Valve open and green
 when at least one valve is normally fully open,
 (3)
 Case 3: Valve amber in a transitional status when rear transfer valve is neither fully open nor fully closed at a time, OR when the forward transfer valve is neither fully closed nor fully open at a time AND the DC2 bus is ON.
 1EFF : ALL 1 31-67-28Page 20 1 1 Aug 01/05 1 1 1CES 1
 (4)
 Case 4: Valve open and amber when both valves are fully open and any transfer valve fails to shut,
 (5)
 Case 5: Valve replaced by amber XX when the valve status is not known, or one received valve status is inconsistent (valve fully closed with valve fully open at a time).
 **ON A/C 301-302,
 D. Item 3 - Center tank fuel quantity
 (Ref. Fig. 007A)
 Digital value from FQI. The display can vary from 0 to 9990 KG with 10 KG
 resolution.
 (1)
 Case 1:
 It is normally displayed in green.
 (2)
 Case 2: In case of degraded data (indication from FQI), the two least significant digits are dashed with amber lines.
 (3)
 Case 3: The value displayed is replaced by amber XX, when the information is not available from the FQI bus.
 (4)
 Case 4: The digital value is displayed in an amber box when the center tank pumps are faulty.
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 E. Item 3 - Left fuel transfer valve
 (Ref. Fig. 004)
 (1)
 Case 1:
 Valve closed and green
 when the valve is normally closed.
 (2)
 Case 2:
 Valve open and green
 when the valve is normally not fully closed
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 31-67-28Page 21 1201-299, 301-302, 401-499, 1Aug 01/05 1 1 1CES 1
 FUEL Page - Display of the Parameters: CENTER TANK PUMPS, CENTER TANK FUEL
 QUANTITY  
R  Figure 007  
R 1EFF : 001-049, 051-099, 101-105, 151-199,  1 Page 2231-67-28 
 1201-299,  1 May 01/05 
 1  1 
 1CES  1
FUEL Page - Display of the Parameters: CENTER TANK PUMPS, CENTER TANK FUEL
 QUANTITY  
R  Figure 007A 
 1EFF :  301-302,  1  31-67-28 Page 23  
1  1  May 01/05 
 1  1 
 1CES  1
 (3)
 Case 3:
 Valve open and amber
 when the valve is abnormally fully open
 (4)
 Case 4:
 Valve closed and amber
 when there is a low level in the wing tank
 (5)
 Case 5: Valve partially open and amber when the valve is neither fully closed nor fully open
 (6)
 Case 6:
 Valve replaced by amber XX
 when the valve status is not known.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 F. Item 4 - Left outer cell temperature
R **ON A/C 106-149, 401-499,
 (Ref. Fig. 005)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 (Ref. Fig. 006)
 **ON A/C 301-399,
 F. Item 4 - Left cell fuel temperature
 Refer to item 2 where the same processing applies.
R **ON A/C 106-149, 401-499,
 Digital value from the FQI. The display can vary from -99 to +99 deg.C with 1 deg.C resolution.
 1EFF : ALL 1 31-67-28Page 24 1 1 Aug 01/05 1 1 1CES 1 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 Digital value from the FQI. The display can vary from -99 to +999 deg.C with 1 deg.C resolution.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 (1)
 Case 1:
 It is normally displayed in green.
 (2)
 Case 2: It becomes pulsing green when either the high or the low temperature advisory is reached.
 (3)
 Case 3: It turns amber when either the high or the low limit of the outer cell temperature is reached.
 