(4)
Case 4: The value displayed is replaced by amber XX, when no valid data are available.
(5)
Case 5: No data is displayed if the outer cell temperature probe is in a dry state.
G. Item 5 - Left outer cell fuel quantity
R **ON A/C 106-149, 401-499,
(Ref. Fig. 003)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
(Ref. Fig. 004)
**ON A/C 301-399,
G. Item 5 - Left cell fuel quantity
Refer to item 1 where the same processing applies.
1EFF : ALL 1 31-67-28Page 25 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Digital value from FQI. The display can vary from 0 to 990 KG, with 10 KG resolution.
(1)
Case 1:
It is normally displayed in green.
(2)
Case 2: In case of degraded data (indication from FQI), the two least significant digits are dashed with two amber lines across.
(3)
Case 3: The value displayed is replaced by amber XX, when the information is not available from the FQI bus.
(4)
Case 4: The digital value is displayed in an amber box when the onside wing transfer valve is faulty.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 31-67-28Page 26 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
**ON A/C ALL
H. Item 6 - Left tank pumps R **ON A/C 106-149, 401-499,
(Ref. Fig. 008)
**ON A/C 303-399,
(Ref. Fig. 008A)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
(Ref. Fig. 009)
**ON A/C 301-302,
(Ref. Fig. 009A)
**ON A/C ALL
(1) Case 1:
The pump symbol is normally displayed in green.
R **ON A/C 106-149, 303-399, 401-499,
(2) Case 2: It turns amber when the pump is not supplied (when the pump contactor is OFF).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(3) Case 2 The pump 1 (the left one whatever the engine 1 or 2) turns amber when the pump1 is not supplied. The pump 2 (the right one) turns amber when the pump2 is not supplied, and the DC2 bus is ON.
1EFF : ALL 1 31-67-28Page 27 1 1 Aug 01/05 1 1 1CES 1
FUEL Page - Display of the Parameters: TANKs PUMPs
Figure 008
R 1EFF : 106-149, 401-499, 1 31-67-28Page 28 1 1 Aug 01/05 1 1 1CES 1
FUEL Page - Display of the Parameters: TANKs PUMPs R Figure 008A
R 1EFF : 303-399, 1 31-67-28Page 29 1 1 May 01/05 1 1 1CES 1
FUEL Page - Display of the Parameters: TANKs PUMPs R Figure 009
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-67-28Page 30 1201-299, 1May 01/05 1 1 1CES 1
FUEL Page - Display of the Parameters: TANKs PUMPs R Figure 009A
R 1EFF : 301-302, 1 31-67-28Page 31 1 1 May 01/05 1 1 1CES 1R **ON A/C 106-149, 303-399, 401-499,
(4) Case 3: In case of low pressure, LO is displayed in amber.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(5) Case 3: In case of low pressure of the pump 1 LO is displayed in amber. In case of low pressure of the pump 2, or if the DC2 bus is OFF, LO is displayed in amber.
**ON A/C ALL
(6) Case 4: It is replaced by amber XX when no valid data are available.
J. Item 7 - APU fire valve R **ON A/C 106-149, 401-499,
(Ref. Fig. 010)
**ON A/C 303-399,
(Ref. Fig. 010A)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
(Ref. Fig. 011)
**ON A/C 301-302,
(Ref. Fig. 011A) R **ON A/C 106-149, 303-399, 401-499,
(1) Case 1 The APU title is white and the triangle and link are normally green.
1EFF : ALL 1 31-67-28Page 32 1 1 Aug 01/05 1 1 1CES 1
FUEL Page - Display of the Parameters: ENGINE FIRE VALVE and APU FIRE VALVE
Figure 010
R 1EFF : 1 1 1CES 106-149, 401-499, 1 111 31-67-28 Page 33 Aug 01/05
FUEL Page - Display of the Parameters: ENGINE FIRE VALVE and APU FIRE VALVE
R Figure 010A
R 1EFF : 303-399, 1 31-67-28 Page 34
1 1 May 01/05
1 1
1CES 1
FUEL Page - Display of the Parameters: ENGINE FIRE VALVE and APU FIRE VALVE
R Figure 011
R 1EFF : 001-049, 05 1201-299, 1 1CES 1-099, 101-105, 151-199, 1 31-67111 Page 35-28May 01/05
FUEL Page - Display of the Parameters: ENGINE FIRE VALVE and APU FIRE VALVE
Figure 011A
R 1EFF : 301-302, 1 31-67-28 Page 36