(1)
 Case 1 The door symbol outline is green when the door is closed (the door locking handle is locked and the door safety mechanism is safe)
 (2)
 Case 2 the door is amber when it is open (the door locking handle is unlocked or the safety mechanism is unsafe) or when a cargo door sensor (syst 1) have an electrical fault
 (3)
 Case 3 the door is replaced by an amber X when the door status is not available from the LGCIU, or when LGCIU1 - L/G door open sensors have an electrical fault
 1EFF : ALL 1 31-67-52Page 27 1 1 Aug 01/05R 1 1 1CES 1
 M. EMER exit operation R **ON A/C 106-149, 303-399, 401-499,
 (Ref. Fig. 008)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 (Ref. Fig. 009)
 **ON A/C ALL
 item 12 The EMER exits follow the same principles as the cabin doors
 (1)
 Case 1 The door symbol outline is green when the door is closed
 (2)
 Case 2
 the door is amber when it is open
 (3)
 Case 3 the door is replaced by an amber X when the door status is not available from the SDAC.
 N. Item 13 (AFT cargo door)
 **ON A/C 001-049, 051-099, 101-105, 201-299,
 (Ref. Fig. 003)
 **ON A/C 151-199,
 (Ref. Fig. 003A)
 **ON A/C 301-302,
 (Ref. Fig. 003B) 
R 1EFF : ALL 1 31-67-52Page 28 1 1 Aug 01/05 1 1 1CES 1
 DOOR/OXY Page - Display of the Parameters: EMER EXITs
 Figure 008
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-52Page 29 1 1 Aug 01/05 1 1 1CES 1
 DOOR/OXY Page - Display of the Parameters: EMER EXITs
 Figure 009
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-67-52Page 30 1201-299, 301-302, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
 (the principles of the cabin doors apply, except the door status which is transmitted by the LGCIU, not by the SDAC).
 (1)
 Case 1 The door symbol outline is green when the door is closed (the door locking handle is locked and the door safety mechanism is safe)
 (2)
 Case 2 the door is amber when it is open (the door locking handle is unlocked or the safety mechanism is unsafe) or when a cargo door sensor (syst 1) have an electrical fault
 (3)
 Case 3 the door is replaced by an amber X when the door status is not available from the LGCIU, or when LGCIU1 - L/G door open sensors have an electrical fault Aft cargo door
 **ON A/C 001-049, 051-099, 101-105, 201-299,
 (Ref. Fig. 003)
 **ON A/C 151-199,
 (Ref. Fig. 003A)
 **ON A/C 301-302,
 (Ref. Fig. 003B)
 **ON A/C 001-049, 051-099, 101-105,
 P. BULK cargo door operation
 Item 14
 The bulk cargo door follows the same principles as the cabin doors:
 (1) Case 1
 green when the door is closed (BULK is not diplayed)
1EFF : ALL 1 31-67-52Page 31 1 1 Aug 01/05R 1 1 1CES 1
 (2)
 Case 2
 amber when the door is open (BULK is displayed in amber)
 (3)
 Case 3 replaced by an amber X when the door status is not available from the SDAC (BULK is displayed in white).
 **ON A/C ALL
 Q. Item 15
 (refer to item 2: cabin door)
 R. Item 16
 (refer to item 2: cabin door)
 S. Item 17
 (refer to item 12: EMER EXIT)
 T. Item 18
 (refer to item 3: Avionic door)
1EFF : ALL 1 31-67-52Page 32 1 1 Aug 01/05 1 1 1CES 1 SYSTEM DISPLAY - ENGINE PAGE - DESCRIPTION AND OPERATION
________________________________________________________
 1. "ENGINE" Page
_____________ R **ON A/C 106-149, 303-399, 401-499,
 The ENGINE Page is described in the following figure with its 9 parameters
 as follows:
 (Ref. Fig. 001)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 The ENGINE Page is described in the following figure with its 10 parameters
 as follows:
 (Ref. Fig. 002)
**ON A/C ALL 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM 指示/记录系统 8(136)