Case 2
Valve closed and amber
When the valve is fully closed as transmitted by the SDAC.
Case 3
Valve position replaced by amber XX
When the valve status is not available from the SDAC.
H. Aft cargo duct temperature
Item 10
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 020)
1EFF : ALL 1 31-67-21Page 41 1 1 Aug 01/05 1 1 1CES 1R COND Page - Display of the parmeters: AFT CARGO UPSTREAM ISOL VALVE, HOT AIR R SHUTOFF VALVE, DOWNSTREAM ISOL VALVE
R Figure 022
R 1EFF : ALL 1 31-67-21 Page 42
1 1 Aug 01/05
1 1
1CES 1
R COND Page - Display of the parameters: AFT CARGO UPSTREAM ISOL VALVE, HOT AIR SHUTOFF VALVE, DOWNSTREAM ISOL VALVE
R Figure 023
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 Page 4331-67-21
1201-299, 301-302, 1 Aug 01/05
1 1
1CES 1
**ON A/C ALL
Refer to the cabin duct temperature, where the same principles apply. (item 6)
J. Aft cargo hot air shutoff valve
Item 11
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 020)
**ON A/C ALL
Case 1 R (Ref. Fig. 022)
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
R (Ref. Fig. 023)
**ON A/C ALL
Valve open and green
Normal case when all other cases are not valid
Case 2
Valve open and amber, when the valve is abnormally open.
Case 3
Valve closed and green
When the valve is normally fully closed
Case 4
Valve closed and amber
When the valve is fully closed and the HOT AIR P/B SW (cargo heat panel)
is in the OFF position.
Case 5
Valve replaced by amber XX
When the valve status is not available from the SDAC.
1EFF : ALL 1 31-67-21Page 44 1 1 Aug 01/05 1 1 1CES 1
K. Aft cargo trim air valve
Item 12
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 020)
**ON A/C ALL
Refer to the cabin trim air valve, as the same principles apply.
L. Aft cargo upstream isolation valve
Item 13
Case 1
R (Ref. Fig. 022)
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
R (Ref. Fig. 023)
**ON A/C ALL
Valve open and green Normal case when the valve is not fully closed as transmitted by the SDAC.
Case 2 Valve closed and amber When the valve is fully closed as transmitted by the SDAC.
Case 3
Valve replaced by amber XX
When the valve status is not available.
R 1EFF : ALL 1 31-67-21Page 45 1 1 Aug 01/05 1 1 1CES 1 SYSTEM DISPLAY - ELEC PAGE - DESCRIPTION AND OPERATION
______________________________________________________
1. "ELEC Page"
___________
The ELEC Page is displayed in the following figure.
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 001) **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 002)
**ON A/C ALL
Item 1: Transformer rectifier 1 operation Item 2: DC busbar 1 indication Item 3: Battery 1 operation Item 4: Essential TR contactor indication Item 5: Battery 1 charge/discharge operation Item 6: DC Battery busbar indication Item 7: Battery 2 charge/discharge operation Item 8: Battery 2 operation Item 9: DC Busbar 2 indication Item 10: Emergency generator operation Item 11: Transformer rectifier 2 operation Item 12: Emergency Generator line contactor Item 13: AC Busbar 2 indication Item 14: Generator 2 operation Item 15: IDG 2 operation indication (low pressure/disconnection)
1EFF : ALL 1 31-67-24Page 1 1 1 Aug 01/05 1 1 1CES 1
SD - ELEC Page: Display of the Parameters 1 to 26
Figure 001
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-24Page 2 1 1 Aug 01/05 1 1 1CES 1
SD - ELEC Page: Display of the Parameters 1 to 26
Figure 002
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 31-67-24Page 3 1201-299, 301-302, 1May 01/05 1 1 1CES 1 1EFF : ALL 1 31-67-24Page 4 1 1 Aug 01/05 1 1 1CES 1 The symbols related to these indications are described hereafter:
R Item 16: IDG 2 outlet temperature indication Item 17: External power operation Item 18: AC Essential busbar indication **ON A/C 106-149, 303-399, 401-499,
Item 19: Galley shed operation message **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 8(97)