 (Ref. Fig. 004A) **ON A/C 301-302,
 (Ref. Fig. 004B) **ON A/C ALL
 (Items 3 and 18)
 The front and aft avionic doors follow the same principles as the cabin doors. The symbol is smaller and horizontal.
 (1)
 Case 1
 The door is green when closed


 (2)
 Case 2
 The door is amber when open

 

R 1EFF : ALL 1 31-67-52Page 12 1 1 Aug 01/05 1 1 1CES 1


 DOOR/OXY Page - Display of the Parameters: AVIONIC DOORs
 Figure 004

R 1EFF : 001-049, 051-099, 101-105, 201-299, 1 31-67-52Page 13 1 1 Aug 01/05 1 1 1CES 1


 DOOR/OXY Page - Display of the Parameters: AVIONIC DOORs
 Figure 004A

R 1EFF : 151-199, 1 31-67-52Page 14 1 1 Aug 01/05 1 1 1CES 1


 DOOR/OXY Page - Display of the Parameters: AVIONIC DOORs
 Figure 004B

R 1EFF : 301-302, 1 31-67-52Page 15 1 1 Aug 01/05 1 1 1CES 1


 (3) Case 3 The door is replaced by an amber X when its status is not available from the SDAC.
 C. Left and right avionic doors **ON A/C 001-049, 051-099, 101-105, 201-299,
 (Ref. Fig. 004) **ON A/C 151-199,
 (Ref. Fig. 004A) **ON A/C 301-302,
 (Ref. Fig. 004B) **ON A/C ALL
 The left and right avionic doors follow the same principles as the cabin doors. The symbol is smaller and vertical.
 (1)
 Case 1
 The door is green when closed


 (2)
 Case 2
 The door is amber when open


 (3)
 Case 3 The door is replaced by an amber X when its status is not available from the SDAC.


 D. Crew oxygen operation
 Item 4

 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 (1) The title OXY is normally green
 1EFF : ALL 1 31-67-52Page 16 1 1 Aug 01/05R 1 1 1CES 1


 (2)
 The OXY indication (normally green) becomes amber when either:

 -there is an oxygen low pressure detected and transmitted by the SDAC,
 -
the OXYGEN CREW SUPPLY pushbutton switch on overhead panel is OFF


 -
the pressure value is lower than 400 psi.
 When these conditions are not available from the SDAC, the OXY title
 remains green.

 


 (3)
 The oxygene pressure value:


 (a) It is displayed
 -
in green when the pressure is more than or equal to 400 psi

 -
in amber when the pressure is less than 400 psi.


 (b) An amber half frame appears when oxygen pressure is less than 1500 psi.

R **ON A/C 106-149, 303-399, 401-499,
 (1)
 The title OXY is normally white

 (2)
 The OXY indication (normally white) becomes amber when either:

 -there is an oxygen low pressure detected and transmitted by the SDAC,
 -
the OXYGEN CREW SUPPLY pushbutton switch on overhead panel is OFF


 -
the pressure value is lower than 400 psi.
 When these conditions are not available from the SDAC, the OXY title
 remains white.

 


 (3)
 The oxygene pressure value:


 (a) It is displayed
 -
in green when the pressure is more than or equal to 800 psi

 -
in amber when the pressure is less than 400 psi


 -pulsing in green, when the pressure is less than 800 psi (the DOOR/OXY page is automatically displayed).
 (b) An amber half frame appears when oxygen pressure is less than 1500 psi. The value is replaced by amber XX when it is not available from the SDAC. The unit is normally cyan.
 1EFF : ALL 1 31-67-52Page 17 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 The value is replaced by amber XX when it is not available from the SDAC.
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 The unit PSI is normally not displayed. R **ON A/C 106-149, 303-399, 401-499,
 The unit PSI is displayed in cyan.
 **ON A/C ALL

 It is not displayed otherwise.
 E. REGUL LO PRESS indication (Item 5) This indication is normally not displayed. It is displayed in amber when there is an oxygen lo press detected and transmitted by the SDAC. It is not displayed when the value is not available from the SDAC.
 F. Display of the vertical speed. R **ON A/C 106-149, 303-399, 401-499,
 (Ref. Fig. 005)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,

 (Ref. Fig. 006)
 **ON A/C ALL

 (Item 6)
 Title V/S

R 1EFF : ALL 1 31-67-52Page 18 1 1 Aug 01/05 1 1 1CES 1
 