A. Item 1 - Transformer rectifier 1 operation
R **ON A/C 106-149, 303-399, 401-499,
The title TR1 is normally white
(Ref. Fig. 003)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
TR is white
1 of TR1 is normally white (item A),
**ON A/C ALL
and also white when the voltage and current displayed below are not available from the SDAC. It is displayed in amber when the voltage or the current is out of range. The voltage (item B) is displayed in green, when inside the range: 25V to 31V. It is displayed in amber when outside this range. The voltage value is replaced by amber XX when it is not available from the SDAC. The display can vary from 0 to 99V. The current (item C) is displayed in green when its value is above 5A. It is displayed in amber when below this value. The current value is replaced by amber XX when it is not available from the SDAC. The display can vary from 0 to 999A.
B. Item 2 - DC busbar 1 indication
Case 1
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 003)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
The outlined DC 1 indication is displayed in green when the bus is on, as transmitted by the SDAC.
1EFF : ALL 1 31-67-24Page 5 1 1 Aug 01/05 1 1 1CES 1
ELEC Page - Display of the Parameters: DC BUSBARs, TRs
Figure 003
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-24Page 6 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 106-149, 303-399, 401-499,
The DC 1 indication is displayed in green when the bus is on, as transmitted by the SDAC.
**ON A/C ALL
Case 2
It is displayed in amber when the bus is off.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
Case 3 It is not displayed (outline empty) when the bus status is not available from the SDAC.
R **ON A/C 106-149, 303-399, 401-499,
Case 3 It is replaced by amber XX when the bus status is not available from the SDAC.
1EFF : ALL 1 31-67-24Page 7 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL
C. Item 3 - Battery 1 operation
BAT 1 is normally displayed in white (item A).
R **ON A/C 106-149, 303-399, 401-499,
(Ref. Fig. 004)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
(Ref. Fig. 005)
**ON A/C ALL
It is displayed in amber when the voltage below or the current is amber. The voltage is normally displayed in green, and displayed in amber when outside the range 25V to 31V. The display can vary from 0 to 99V. The current is normally displayed in green, and displayed in amber when below -5A. The display can vary from 0 to 999A. These digital values for the voltage or the current are replaced by amber XX when the related data are not available from the SDAC. The set of information voltage/current is displayed only when the BAT1 P/B SW is ON, as rtansmitted by the BCL via the SDAC. When it is OFF, or when the information is not available from the SDAC, the voltage/current is replaced by OFF.
D. Item 4 - Essential TR contactor indication
Refer to the para. ELEC Page links below.
E. Item 5 - Battery 1 charge/discharge operation
Refer to the para. ELEC Page links below.
F. Item 6 - DC Battery busbar indication Case 1 DC BAT is normally displayed in green, when the voltage of the battery bus 3PP is over 25V, as transmitted by the BCL1, or the BCL2 via the SDAC.
1EFF : ALL 1 31-67-24Page 8 1 1 Aug 01/05 1 1 1CES 1
ELEC Page - Display of the Parameters: BATTERY OPERATION, BATTERY BUSBAR, DC
ESS BUSBAR
Figure 004
R 1EFF : 106-149, 303-399, 401-499, 1 31-67-24 Page 9
1 1 Aug 01/05
1 1
1CES 1
ELEC Page - Display of the Parameters: BATTERY OPERATION, BATTERY BUSBAR, DC
ESS BUSBAR
Figure 005
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 Page 1031-67-24
1201-299, 301-302, 1 May 01/05
1 1
1CES 1