曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
b) Release the control column.
(aa) Move and hold the control column full forward.
1) Use a scale to make sure the trailing edge of the left elevator is in 10.18 - 11.08 inches
(258.6 - 281.4 mm) of the index mark.
2) Use a 6 inch (150 mm) scale to measure from the bottom edge of the left elevator to the
bottom edge of the elevator tab (this is referred to as the "up tab position").
a) Make a record of this up tab position.
b) Release the control column.
(ab) Add the neutral tab position to the down tab position.
1) Make sure the sum is 1.35 - 1.69 inches (34.3 - 42.9 mm).
(ac) Subtract the neutral tab position from the up tab position.
1) Make sure the difference is 1.00 - 1.28 inches (25.4 - 45.7 mm).
(ad) Open this circuit breaker and install safety tag:
F/O Electrical System Panel, P6-2
Row Col Number Name
B 8 C01464 FLIGHT CONTROL ELEV TAB VLV RIGHT
(ae) Move the flap control lever to the 5-unit position.
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-31-00
Page 572
Jun 10/2007
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
(af) Remove the safety tag and close this circuit breaker:
F/O Electrical System Panel, P6-2
Row Col Number Name
B 8 C01464 FLIGHT CONTROL ELEV TAB VLV RIGHT
1) Make sure that the right tab begins to move in 10 +/- 2 seconds.
(ag) Lightly move the control column forward and aft a small amount to make sure that the
system is in the neutral position.
(ah) Verify that the right elevator is aligned with the index mark in +/- 0.06 inch (+/- 1.5 mm).
1) Use a 6 inch (150 millimeter) scale to measure from the bottom edge of the right
elevator to the bottom edge of the elevator tab (this is referred to as the "neutral tab
position).
a) Make a record of this neutral tab position.
(ai) Move and hold the control column full aft.
1) Use a scale to make sure the trailing edge of the right elevator is in 13.73 - 14.87 inches
(348.7 - 377.7 millimeters) of the index mark.
2) Use a 6 inch (150 millimeter) scale to measure from the bottom edge of the right
elevator to the bottom edge of the elevator tab (this is referred to as the "up tab
position").
a) Make a record of this up tab position.
b) Release the control column.
(aj) Move and hold the control column full forward.
1) Use a scale to make sure the trailing edge of the right elevator is in 10.18 - 11.08 inches
(258.6 - 281.4 mm) of the index mark.
2) Use a 6 inch (150 mm) scale to measure from the bottom edge of the right elevator to
the bottom edge of the elevator tab (this is referred to as the "down tab position").
a) Make a record of this down tab position.
b) Release the control column.
(ak) Add the neutral tab position to the up tab position.
1) Make sure the sum is between 0.80 and 1.20 inches (20.3 and 30.5 mm).
(al) Subtract the neutral tab position from the down tab position.
1) Make sure the difference is between 0.60 and 0.90 inches (15.2 and 22.9 mm).
(am) Move the left elevator by hand to align it with the index mark in +/- 0.06 inch (+/- 1.5 mm).
1) Use a 6 inch (150 millimeter) scale to measure from the bottom edge of the left elevator
to the bottom edge of the elevator tab (this is referred to as the "neutral tab position").
a) Make a record of this neutral tab position.
(an) Move and hold the control column full aft.
1) Use a scale to make sure the left elevator is in 13.73 - 14.87 inches (348.7 - 377.7 mm) of
the index mark.
(ao) Use a 6 inch (150 millimeter) scale to measure from the bottom edge of the left elevator to
the bottom edge of the elevator tab (this is referred to as the "up tab position").
1) Make a record of this up tab position.
(ap) Move and hold the control column full forward.
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-31-00
Page 573
Jun 10/2007
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
1) Use a scale to make sure the trailing edge of the left elevator is in 10.18 - 11.08 inches
(258.6 - 281.4 mm) of the index mark.
2) Use a 6 inch (150 millimeter) scale to measure from the bottom edge of the left elevator
to the bottom edge of the elevator tab (this is referred to as the "down tab position").
a) Make a record of this down tab position.
b) Release the control column.
(aq) Add the neutral tab position to the up tab position.
1) Make sure the sum is between 0.80 and 1.20 inches
(20.3 - 30.5 mm).
(ar) Subtract the neutral tab position from the down tab position.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
737-600/700/800/900 AIRCRAFT MAINTENANCE MANUAL飞机维护手册2(155)