Pressure Removal (P/B 201)
FIM 27-31 TASK 810 Elevator Does Not Move Correctly - Fault Isolation
SRM 51-60-04 Structural Repair Manual
C. Tools/Equipment
NOTE: When more than one tool part number is listed under the same "Reference" number, the
tools shown are alternates to each other within the same airplane series. Tool part numbers
that are replaced or non-procurable are preceded by "Opt:", which stands for Optional.
Reference Description
COM-1557 Gauge - Force
(Part #: DG-200, Supplier: 92456, A/P Effectivity: 737-ALL)
(Part #: DPP-500G, Supplier: 92456, A/P Effectivity: 737-ALL)
(Part #: DPPH-150, Supplier: 92456, A/P Effectivity: 737-ALL)
(Part #: DPPH-50, Supplier: 92456, A/P Effectivity: 737-ALL)
(Part #: FDIX 100, Supplier: 0BFD9, A/P Effectivity: 737-ALL)
(Part #: FDIX 50, Supplier: 0BFD9, A/P Effectivity: 737-ALL)
(Part #: FDV 50, Supplier: 0BFD9, A/P Effectivity: 737-ALL)
(Opt Part #: FDI 100, Supplier: 0BFD9, A/P Effectivity: 737-ALL)
SPL-1677 Assembly - Trammel Bar, Stabilizer Trim Actuator
(Part #: F80055-1, Supplier: 81205, A/P Effectivity: 737-100, -200,
-200C, -300, -400, -500, -600, -700, -700C, -700ER, -700QC, -800, -900,
-900ER, -BBJ)
STD-1278 Block - Loading, 1/8 Inch Thick, 3 Inch by 3 Inch Wood or Fiberglass
Block with Pad to Prevent Damage to the Skin.
D. Location Zones
Zone Area
211 Flight Compartment - Left
212 Flight Compartment - Right
334 Left Horizontal Stabilizer - Elevator
344 Right Horizontal Stabilizer - Elevator
E. Access Panels
Number Name/Location
311BL Stabilizer Trim Access Door
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-31-00
Page 559
Jun 10/2007
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
F. Prepare for the Test
SUBTASK 27-31-00-860-046
(1) Do this task: Remove Pressure from the Elevator Hydraulic Systems A and B,
TASK 27-31-00-800-802.
SUBTASK 27-31-00-860-047
(2) Do this task: Null Procedure - Mach Trim Actuator, TASK 27-31-00-700-801.
SUBTASK 27-31-00-010-007
(3) Open this access panel:
Number Name/Location
311BL Stabilizer Trim Access Door
SUBTASK 27-31-00-860-048
(4) Use the bar, SPL-1677 to set the "B" dimension at 4 units of trim (39.89 +/- 0.05 inches or 1013.2
+/- 1.3 mm) (Figure 502).
SUBTASK 27-31-00-860-049
(5) Move the control columns in a longitudinal (forward to aft) direction through full travel 20 times.
G. Elevator Surface Friction and Balance Test
SUBTASK 27-31-00-730-001
CAUTION: DO NOT PUT A LOAD OF MORE THAN 65 POUNDS (289 NEWTONS) ON THE
ELEVATORS AT ONE TIME. IF THE LOAD IS TOO HEAVY, IT CAN CAUSE DAMAGE TO
THE ELEVATORS.
(1) Do the elevator surface friction and balance test:
(a) Hold the captain’s control columns at the neutral position.
(b) Move the elevator with your hand until the right elevator trailing edge aligns with the
elevator neutral index mark (Figure 505).
1) Release the elevator trailing edge.
(c) If the right elevator trailing edge moves down from the index mark, then do the elevator
balance adjustment (SRM 51-60-04).
(d) If the right elevator trailing edge moves up from the index mark, then do these steps:
WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF ALL
CONTROL SURFACES BEFORE YOU SUPPLY HYDRAULIC POWER.
AILERONS, RUDDERS, ELEVATORS, FLAPS, SPOILERS, SLATS, AND
THRUST REVERSERS CAN MOVE QUICKLY WHEN YOU SUPPLY
HYDRAULIC POWER. THIS CAN CAUSE INJURY TO PERSONS AND
DAMAGE TO EQUIPMENT.
1) Turn on the A and B hydraulic systems to center the elevator, do this task: Elevator
Hydraulic System A and B - Pressurization, TASK 27-31-00-800-801.
2) Do this task: Remove Pressure from the Elevator Hydraulic Systems A and B,
TASK 27-31-00-800-802.
3) Hold the captain’s control column in the neutral position.
4) Use the block, STD-1278 and force gauge, COM-1557 to measure the minimum force
required to move the elevator trailing edge down 0.75 +/- 0.15 inch (19.1 +/- 3.8 mm)
(1.25 +/- 0.24 degrees) from the neutral index mark (this force is referred to as the
"down force").
737-600/700/800/900
AIRCRAFT MAINTENANCE MANUAL
EFFECTIVITY
GUN ALL 27-31-00
Page 560
Jun 10/2007
D633A101-GUN
BOEING PROPRIETARY - Copyright#Unpublished Work - See title page for details
a) Make a record of this down force.
5) Hold the captain’ control column in the neutral position.
6) Use the block, STD-1278 and force gauge, COM-1557 to measure the minimum force
required to hold the elevator trailing edge at the index mark (which is referred to as the
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-600/700/800/900 AIRCRAFT MAINTENANCE MANUAL飞机维护手册2(148)