~.............................................................................. | MM | | IPC | ................. ............................ | FIG | ITEM | NOMENCLATURE | SUBJECT | FIG | ITEM | ................................................................................ | 401 | 1 | Packing | 28-11-04 | 01 | 15,35| | | 2 | Packing | | | 25 | | | 3 | Primary Poppet | 28-11-04 | 01 | 20 | | | 4 | Poppet Seat | | | 30 | 2......…........…...................................…..........….....….........1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-04
ALL ú ú 01 Page 402 ú Oct 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
SURGE TANK SUMP DRAIN SEE A
NO. 3 RESERVE TANK SUMP DRAIN NO. 4 MAIN TANK SUMP DRAIN
SEE B
SEE B
SURGE TANK SUMP DRAIN
SEE A
NO. 3 MAIN TANK SUMP DRAIN
SEE A
NO. 2 MAIN TANK NO. 2 RESERVE TANK
SUMP DRAIN SUMP DRAIN
CENTER WING SEE A NO. 1 MAIN TANK SEE B
TANK SUMP DRAIN SUMP DRAIN
SEE A SEE B
(CONNECTED TO
FUEL SUMP DRAIN LINE)
DRAIN VALVE FUEL SUMP
DRAIN VALVE
LOWER WING OR LOWER WINGSTABILIZER SKIN OR BODY SKIN
2.
PACKING
3.
PRIMARY POPPET 3. PRIMARY POPPET
2. PACKING
4.
POPPET SEAT
4. POPPET SEAT
1. PACKING 1. PACKING
SUMP DRAIN SUMP DRAIN (EXAMPLE) (EXAMPLE)
A B
Fuel Sump Drain Valve Primary Poppet Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-04
ALL ú ú 03 Page 403 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
D. Access
(1)
Location Zones 131 Center Section Wing Box, Left 132 Center Section Wing Box, Right 541 Inbd Main Tank (Part), Front Spar to Mid Spar, Left 545 Inbd Main Tank (Part), Mid Spar to Rear Spar, Left 552 Outbd Main Tank (Part), Mid Spar to Rear Spar, Left 555 Surge Tank, Front Spar to Rear Spar, Left 641 Inbd Main Tank (Part), Front Spar to Mid Spar, Right 645 Inbd Main Tank (Part), Mid Spar to Rear Spar, Right 652 Outbd Main Tank (Part), Mid Spar to Rear Spar, Right 655 Surge Tank, Front Spar to Rear Spar, Right
(2)
Access Panels
191GL Fuel Drain and Dripstick Access Door
192GR Fuel Drain and Dripstick Access Door
E.
Procedure
S 114-020
WARNING: DO NOT GET SOLVENTS IN YOUR MOUTH, OR YOUR EYES, OR ON YOUR
_______ SKIN. DO NOT BREATHE THE FUMES FROM SOLVENTS. SOLVENTS ARE HAZARDOUS MATERIALS. SOLVENTS MAY BE FLAMMABLE. REFER TO PRODUCT MATERIAL SAFETY DATA SHEETS (MSDS) AND LOCAL REQUIREMENTS FOR PROPER HANDLING PROCEDURES.
(1)
Clean the base and poppet seat (4) with solvent, Series 82
(AMM 20-30-82/201) to remove all lubricant.
S 434-007
(2)
Install the new packing (1) on the poppet seat (4).
S 434-008
(3)
Install the new packing (2) on the primary poppet (3).
(4)
Assemble the poppet (3) in the poppet seat (4).
S 644-010
(5)
Apply a thin layer of antiseize compound to the external threads of poppet seat (4).
S 434-009
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-04
ALL ú ú 07 Page 404 ú Jun 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 644-018
(6) Apply a thin layer of antiseize compound to the internal threads of
the fuel sump drain valve.
S 424-011
(7) For all the fuel sump drain valve locations except the No. 2 or
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 燃油 FUEL 1(119)