28-11-00
ALL ú ú 01 Page 828 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
CAUTION: MAKE SURE THE TEMPERATURE OF THE TANK SURFACE THAT
_______ YOU APPLY THE SEALANT TO IS AT A TEMPERATURE EQUAL TO OR MORE THAN THE AMBIENT TEMPERATURE. IF THE RELATIVE HUMIDITY IS LARGE, CONDENSATION FORMS IF THE TEMPERATURE OF THE METAL SURFACE IS LESS THAN THE AMBIENT TEMPERATURE. THE TANK SURFACE MUST BE DRY TO APPLY THE SEALANT.
4) For BMS 5-26 Type II or BMS 5-45 sealant, if you keep the humidity constant, the times, shown in (Fig. 804), change as follows for each 20°F (11°C) change in temperature: a) Tack-free times are approximately one-half as long for
each 20°F (11.1°C) increase in temperature. b) Tack-free times are approximately double for each 20°F (11.1°C) decrease in temperature.
H. Apply the Sealant
S 368-247
(1) To apply the precoat do these steps:
NOTE: A precoat of BMS 5-26 Type II Class A-2 sealant is brushed
____ into the repair area, prior to the fillet seal application.
NOTE: Precoat is optional when you use Pro-Seal 860,
____ B 1/6 sealant. A special primer is used with PR-1826 sealant. Obey the manufacturers instructions.
(a)
Examine the seal area to make sure you have the correct selection of tools for the job.
(b)
Apply a precoat of correctly mixed BMS 5-26 Type II Class A-2 sealant to the surface with a stiff bristled brush (Fig. 805). 1) Make sure you apply precoat into all crevices and the full
length of the area that you will apply sealant to. 2) Apply the precoat at a width of 1/2 inch (12.7 mm) on each side of seams. 3) Make sure the precoat is applied smoothly.
(c)
If you let the precoat become hard, clean with Series 93 solvent (AMM 20-30-93/201), before you apply the fillet seal.
NOTE:____It is not necessary to let the precoat cure. A minimum tack-free time of 15 to 20 minutes is recommended.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-00
ALL ú ú 01 Page 829 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 368-249
(2) To apply the first fillet seal, do these steps:
NOTE: You must apply the fillet seal in two applications, a small
____ first fillet seal, and a final fully body, second fillet seal. If you do not use a first fillet seal, fuel leaks can occur in service.
(a) Make sure the precoat is applied correctly.
NOTE: Precoat is optional when you use Pro-Seal 860, B 1/6
____ sealant. A special primer is used with PR-1826 sealant. Obey the manufacturers instructions.
CAUTION: MAKE SURE YOU APPLY THE FILLET SEAL CAREFULLY TO PREVENT
_______ AIR BUBBLES IN THE SEALANT. THE FILLET SEAL WILL NOT BOND CORRECTLY IF THERE ARE AIR BUBBLES IN THE SEALANT.
(b)
Apply a small fillet seal of BMS 5-26 Type II, Class B or BMS 5-45 Class B sealant (or equivalent) with the sealant gun (Fig. 806). 1) When you use a nozzle tip, point the nozzle tip into the
seam, almost perpendicular to the direction of travel. Keep a bead of solvent in front of the nozzle tip. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 燃油 FUEL 1(100)