Plot a point with the maximum EGT and the time the EGT was over the limit in that area.

 S 816-062-C00

 (2)  
Obey the instructions given for each area as follows:


 (a)  If the point is in area A:
 1)  If you find that the N1 rotor stopped during the hot start, do the borescope inspection procedure for the 1st-stage LPT blades.
 2)  A maximum service extension of one start is permitted.
 a)  If that start is a normal start, one cycle is permitted before you must do the troubleshooting procedure to find and correct cause of the hot start (AMM 71-00-41/101).
 b)  If that start results in another hot start, you must do the troubleshooting procedure to find and correct the problem before the next flight (AMM 71-00-41/101).
 (b)  If the point is in area B, do these steps before the next flight: 1) You must do a borescope inspection of the HPT blades and
 the 1st-stage LPT blades. 2) Do the trouble shooting procedure to find the cause of the hot start (AMM 71-00-41/101).
 3)  A maximum service extension of one start is permitted and, if that start is satisfactory, 1 cycle is permitted before you must correct the problem.
 (c)  If the point is in area C, do these steps before you start the engine again: 1) Do the borescope inspections of the HPT blades and the
 1st-stage LPT blades. 2) Do the trouble shooting procedure to find the cause of the hot start (AMM 71-00-41/101).
 E.  Engine Overtemperature - Not Starting (Fig. 611).
 NOTE:____ There can be many causes of an EGT overtemperature.  Some examples
 are:
 - N1 overboost
 - Too much air bleed
 - Engine deterioration
 - Temperature inversion during the takeoff

 -Engine warm up time is not sufficient before the takeoff.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú C01 Page 682G ú Mar 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////

970
965 955 950
945 940 930 920 910 900
895 890 880 870 860 850 840 830 820
EGT `C

S-M56-MM-1884-03-B
Exhaust Gas Temperature (EGT)
Overtemperature Inspection Requirements (Except Starting)
Figure 611 (Sheet 1)

F08975
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú C02 Page 682H ú Mar 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////
EGT `C
970

965
960
955
950
945
940

1
935
930

1  ON AIRPLANES WITH EGT TRANSIENT OVERTEMPERATURE CAPABILITY OR SERVICE BULLETIN, NO MAINTENANCE ACTION IS NECESSARY WHEN THE EGT MAXIMUM IS BETWEEN 930` AND 940`C FOR LESS THAN 20 SECONDS 925 WHEN TAKEOFF OR GO-AROUND POWER IS SET. REFER TO BOEING SERVICE LETTER 737-SL-72-006 FOR MORE INFORMATION.
S-M56-MM-02471-00-B

Exhaust Gas Temperature (EGT)
Overtemperature Inspection Requirements (Except Starting)
Figure 611 (Sheet 2)

C76047
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú C02 Page 682I ú Mar 12/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / /
CFM56 ENGINES
737-300/400/500/ /MAINTENANCE MANUAL ////////////////////////
Engine Operations Above the Limits and High Engine Stress Inspection
_____________________________________________________________________
 S 976-148-C00
 (1)  
Put a point on the graph to show the maximum EGT and the time the EGT was over the redline limit.

 S 816-149-C00

 (2)  
Follow the instructions given for each area where the point is found:
 