49-41-51
ALL ú ú 01 Page 701 ú Jul 15/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / GTCP85-129 SERIES /737-300/400/500/ ENGINES/MAINTENANCE MANUAL ////////////////////////
(b) Dry the igniter plug with the clean compressed air.
CAUTION: DO NOT USE HARD GRIT OR A STEEL BRUSH TO CLEAN THE IGNITER
_______
PLUG. DAMAGE TO THE PLUG CAN OCCUR.
(c)
Clean all the unwanted materials off the igniter plug with a brush that has brass bristles.
(d)
Blow all the loose material off the igniter plug with the clean compressed air that is not moist.
S 417-004
(3) Install the igniter plug (AMM 49-41-51/401).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
49-41-51
ALL ú ú 01 Page 702 ú Jul 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
IGNITER CABLE - REMOVAL/INSTALLATION
____________________________________
1. General_______
A. This procedure gives the steps to remove and to install the igniter cable. The igniter cable connects the igniter plug on the combustion chamber cap to the ignition unit.
TASK 49-41-52-004-001
2. Igniter Cable Removal (Fig. 401)_____________________
A. Access
(1)
Location Zones
101 Control Cabin (Left)
205 Electronic Compartment
703 APU Compartment
(2)
Access Panels
1201 Electronic Equipment Access Door
3804 APU Cowl Door
B. Procedure
S 864-002
(1) Set the switch and the circuit breaker:
(a)
Set the APU master switch, on the P5 forward overhead panel, to the OFF position and attach a DO-NOT-OPERATE tag.
(b)
Open this circuit breaker and attach a DO-NOT-CLOSE tag: 1) E3-3 Electrical Shelf, APU Control Unit
S 014-003
(2) Open the APU cowl door:
(a)
Open the latches for the APU cowl door.
(b)
Open the APU cowl door.
(c)
Connect the door support rods.
S 014-004
CAUTION:_______BE CAREFUL WHEN YOU MOVE THE LOWER SHROUD. DAMAGE TO THE SHROUD DRAIN LINES CAN OCCUR.
(3) Remove the lower shroud:
(a)
Hold the lower shroud and open the shroud latches.
(b)
Remove the lower shroud.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
49-41-52
ALL ú ú 01 Page 401 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / GTCP85-129 SERIES /737-300/400/500/ ENGINES /MAINTENANCE MANUAL ////////////////////////
SEE B
SEE A
A
IGNITER PLUG
OIL TANK COMBUSTION
(REF) CHAMBER
CAP (REF)
IGNITION
UNIT
IGNITER FWD
CABLE
B
Igniter Cable Installation
Figure 401
A48645
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
49-41-52
ALL ú ú 01 Page 402 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
S 034-005
WARNING: DO NOT TOUCH THE IGNITION COMPONENTS UNTIL YOU DO THESE STEPS.
_______ THESE STEPS WILL RELEASE THE HIGH VOLTAGE FROM THE IGNITION UNIT. IF YOU DO NOT OBEY THIS PROCEDURE, INJURY TO PERSONS CAN OCCUR.
(4) Do these steps to release the high voltage from the ignition unit:
(a)
Make sure 5 minutes have gone by since the last APU start.
(b)
Disconnect the igniter cable from the igniter plug.
(c)
Ground the igniter cable to the APU.
S 024-006
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 AIRBORNE AUXILIARY POWER 2(56)