(2)
IPC 25-31-13
C. Access
(1) Location Zone
200 Upper Half Fuselage
D. Procedure
S 027-010
(1)
Remove the wing bolts from the strainer assembly.
S 027-002
(2)
Remove the strainer element from the strainer housing (AMM 25-31-13/401).
(3)
Remove all of the unwanted materials from the strainer element.
S 167-004
(4)
Clean the strainer element fully with a weak detergent and water that is warm.
S 147-003
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
25-31-13
ALL ú ú 01 Page 701 ú Feb 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
WATER FILTER (REF)
DRAIN
DRAIN LINES
LINES
SINK
STRAINER
SEE A
CLAMP
ATTACHMENT SCREW
AND WASHER
(3 LOCATIONS)
GALLEY
DRAIN HOSE
FLOOR
DRAIN
WASHER FITTING
GALLEY DRAIN LINE STRAINER INSTALLATION
FOR THE GALLEY DRAIN LINE
SCREW WING O-RING (EXAMPLE)
BOLT
STRAINER
HOUSING
STRAINER
ELEMENT
CLAMP (2)
1-INCH
DRAIN
HOSE
STRAINER
A
Galley Drain Line Strainer
Figure 701
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
25-31-13
ALL ú ú 01 Page 702 ú Feb 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(5) S 167-005Clean the rubber O-ring and all the mating surfaces to make sure you get a satisfactory seal after installation. (a) Replace a damaged or worn O-ring seal.
(6) S 427-006Install the strainer element into the strainer housing (AMM 25-31-13/401).
(7) S 427-011Install the wing bolts on the strainer assembly.
(8) S 167-012Clean the surrounding area of the drain strainer. (a) Remove all liquid and debris that may have spilled below the drain strainer. (b) Place all waste material in a plastic bag for disposal. (c) Clean all liquid with an absorbant towel.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
25-31-13
ALL ú ú 01 Page 703 ú Feb 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
GALLEY VENTILATION INLET FILTER - MAINTENANCE PRACTICES
_______________________________________________________
1. General
_______
A. This procedure gives the instructions to clean the inlet filter for the galley ventilation system.
B. To clean the inlet filter you must remove, clean and install the filters. Clean the filters regularly to make sure that the galleys have sufficient ventilation.
TASK 25-31-17-102-001
2. Galley Ventilation Inlet Filter Cleaning (Fig. 201)
________________________________________
A. Standard Tools and Equipment
(1) Bucket
B. Access
(1) Location Zone
200 Upper Half Fuselage
C. Procedure
S 112-009
(1) Prepare the solvent:
(a) Put the soap with the water in a bucket.
NOTE: A sufficient quantity of soap with water must
____ be used to clean the filter.
S 032-002
(2)
Remove the fasteners and washers which attach the grill to the inlet assembly.
(3)
Remove the filter from the grill.
S 112-010
(4)
Clean the filter:
S 022-008
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 EQUIPMENT/FURNISHINGS 1(83)