 (5)  S 865-025Turn the test switch S2, on the test equipment, to the NO TRIP position.
 (6)  S 725-062Push the test switch S1. (a) Make sure the light L1 comes on.
 (7)  S 725-063Release the test switch S1.
 (8)  S 725-064Turn the test switch S2 to the TRIP position. (a) Make sure the light L1 goes out.
 (9)  S 725-065Set the test switch S2 to the NO TRIP position. (a) Make sure the light L1 stays out.
 S 865-033

 (10) Momentarily push the reset button on the ground fault detector for hydraulic system A.
 NOTE: The reset button is located in the upper inboard corner of
____ the bulkhead behind the hinged P6-2 panel on the ground fault detector (M1105).
 S 725-066
 (11) Push the test switch S1.
 (a) Make sure the light L1 comes on.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ú ú 02 Page 504 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-036
 (12) Set the HYD PUMPS A ELEC 2 switch to the OFF position.
 (a)  Make sure the test light L1 goes out.
 S 865-038
 (13) Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  
P6-2 Panel
 1) ELEC HYD PUMP CONT SYS A


 (b)  
P6-12 Panel
 1) ELEC HYD PUMP SYS A

 

 S 865-039
 (14) Disconnect the test equipment connector from the electrical
 connector for the system A EMDP.

 F. System B Ground Fault Detector Test
 S 035-068
 WARNING: YOU MUST CONNECT THE GROUNDING CABLE FOR THE TEST EQUIPMENT TO
_______ THE AIRPLANE GROUND BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR FOR THE PUMP TO THE TEST EQUIPMENT. INJURY TO PERSONS CAN OCCUR.
 (1)  
Disconnect the electrical connector from the system B EMDP.

 S 865-040

 (2)  
Connect the test equipment connector to the electrical connector for the EMDP.

 S 865-041

 (3)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:

 (a)  
P6-2 Panel
 1) ELEC HYD PUMP CONT SYS B


 (b)  
P6-11 Panel
 1) ELEC HYD PUMP SYS B

 

 

 S 865-042
 (4)  
Set the HYD PUMPS B ELEC 1 switch, on the P5 panel, to the ON position.

 S 725-069

 (5)  
Turn the test switch S2, on the test equipment, to the NO TRIP position.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ú ú 02 Page 505 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 (6)  S 725-070Push the test switch S1. (a) Make sure the light L1 comes on.
 (7)  S 725-072Release the test switch S1.
 (8)  S 725-071Turn the test switch S2 to the TRIP position. (a) Make sure the light L1 goes out.
 (9)  S 725-073Set the test switch S2 to the NO TRIP position. (a) Make sure the light L1 stays out.
 S 865-051

 (10) Momentarily push the reset button on the ground fault detector for hydraulic system B.
 NOTE: The reset button is located in the lower inboard corner of
____ bulkhead behind the hinged P6-1 panel on the Ground Fault Detector (M1106).
 S 725-074
 (11) Push the test switch S1.
 (a)  Make sure the light L1 comes on.
 S 865-054
 (12) Set the HYD PUMPS B ELEC 1 switch to the OFF position.
 (a)  Make sure the test light L1 goes out.
 S 865-056
 (13) Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  P6-2 Panel 1) ELEC HYD PUMP CONT SYS B
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ú ú 02 Page 506 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(96)