• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 15:00来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

LINE 

PRESSURE 
LINE  50` 
ISOLATION  GROUNDING  40` 
MOUNT  ACOUSTIC  SUPPLY  STRAP 
(EXAMPLE)  FILTER  LINE 
SYSTEM B EMDP 
C  FWD 

1
PUT THE HYDRAULIC HOSE IN THE POSITION SHOWN.
B-B
IN OTHER POSITIONS IT WILL RUB THE ELECTRICAL WIRES.
Hydraulic Systems A and B EMDP Removal/Installation
Figure 401 (Sheet 2)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ALL  ú ú 01 Page 403 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 034-042
 CAUTION: MAKE SURE THAT YOU PULL DOWN ON THE KNURLED RING OF THE
_______ SELF-SEAL DISCONNECT BEFORE YOU TURN IT FOR REMOVAL. IF YOU DO NOT DO THIS, TOO MUCH TORQUE WILL BE NECESSARY TO TURN THE RING WHICH WILL DAMAGE THE SELF-SEAL DISCONNECT.
 (3)  Disconnect the pump supply line at the quick-disconnect.
 NOTE:  The quick-disconnect for system A is on the bottom of the system A reservoir. The quick-disconnect for system B is outboard of the EMDP.
 F. Remove the Pump (Fig. 401)
 S 034-005
 (1)  
Disconnect the electrical connector from the pump.

 S 034-006

 (2)  
Disconnect the supply line from the pump and drain the fluid out of it.

 S 034-007

 (3)  
Put a cap on the supply line to keep contamination out.

 S 034-008

 (4)  
Disconnect the case drain line from the pump and drain the fluid out of it.

 S 034-009

 (5)  
Put a cap on the case drain line to keep contamination out.

 S 034-010

 (6)  
Disconnect the strap that holds the acoustic filter.

 (7)
Disconnect the acoustic filter (the pressure line) from the pump.

 (8)  
Put a cap on the pressure line to keep contamination out.

 (9)
Put caps on the supply, pressure, and case drain ports of the pump.

 (10)
 Remove the mounting bolts and disconnect the bonding jumper.

 (11)
 Remove the pump from the airplane.


 S 034-011
 S 034-012
 S 034-013
 S 024-014
 S 024-018
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-22
 ALL  ú ú 02 Page 404 ú Jul 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 174-017
 (12) If the pump is being replaced because of a mechanical failure, do these steps:
 (a)  
Replace the filter element of the case drain filter.

 (b)  
Replace the acoustic filter (AMM 29-15-27/401) if it has contamination (metal particles) in it.

 (c)  
Replace the filter element for the pressure filter (AMM 29-15-71/201).

 (d)  
Flush the hydraulic system (AMM 29-15-00/201).


 TASK 29-15-22-404-019
 3. Install the Electric Motor-Driven Pump (EMDP)
_____________________________________________
 A. References
 (1)  
AMM 12-12-00/301, Hydraulic Servicing

 (2)  
AMM 12-40-00/201, Cleaning and Washing

 (3)  
AMM 20-10-34/701, Metal Surfaces

 (4)  
SWPM 20-20-00, Standard Wiring Practices Manual

 (5)  
AMM 29-09-00/201, Hydraulic Reservoir Pressurization System

 (6)  
AMM 29-15-00/201, Hydraulic Systems A, B, and Standby


 B. Access
 (1)  Location Zones
 216/217 Left/Right Main Wheel Well

 C. Prepare for the Installation
 S 434-020
 (1)  Make sure the pump assembly has all of its parts. If the fittings and the O-rings are not installed, install them with assembly lube or hydraulic fluid. Put caps on all of the ports.
 NOTE: All of the fittings and the O-rings should be installed on or
____
 supplied with the pump assembly.

 S 104-021
 (2)  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(92)