P6-3 Panel 1) INDICATOR MASTER DIM BUS BAT 2) INDICATOR MASTER DIM BUS NO. 1 DC 3) INDICATOR MASTER DIM BUS NO. 2 DC 4) INDICATOR MASTER DIM BUS SECT 1 5) INDICATOR MASTER DIM BUS SECT 2 6) INDICATOR MASTER DIM BUS SECT 3 7) INDICATOR MASTER DIM BUS SECT 4 8) INDICATOR MASTER DIM BUS SECT 5 9) INDICATOR MASTER DIM BUS SECT 6

 (c)  
P6-4 Panel
 1) AC INDICATION BUS NO. 1 C

 

 

 S 865-024
 (3)  Open these circuit breakers:
 (a)  
P6-11 Panel
 1) STBY HYD PUMP NORMAL


 (b)  
P6-12 Panel
 1) STBY HYD PUMP ALTERNATE

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 504 ú Jul 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-025
 WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF ALL CONTROL
_______ SURFACES BEFORE YOU SUPPLY HYDRAULIC POWER. THE AILERONS, RUDDER, ELEVATORS, FLAPS, SLATS, SPOILERS, LANDING GEAR, AND THRUST REVERSERS CAN MOVE QUICKLY WHEN YOU SUPPLY HYDRAULIC POWER. THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (4)  
Supply hydraulic power to system B (Ref 29-15-00/201).

 S 865-026

 (5)  
Set the flap control lever in the one unit position.

 S 865-027

 (6)  
Remove hydraulic power from system B (Ref 29-15-00/201).


 D. Procedure
 S 865-028
 (1)  
Put the FLT CONTROL A switch (on the P5 panel) in the STDBY RUD position.

 S 215-029

 (2)  
Make sure the STANDBY HYD LOW PRESSURE light (on the P5 panel) is on.


 S 865-030
 WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF THE RUDDER,
_______ THRUST REVERSERS, AND LEADING EDGE SLATS. THEY CAN MOVE QUICKLY WHEN YOU SUPPLY STANDBY HYDRAULIC POWER.
 (3)  
Close these circuit breakers:

 (a)  
P6-11 Panel
 1) STBY HYD PUMP NORMAL


 (b)  
P6-12 Panel
 1) STBY HYD PUMP ALTERNATE

 


 (4)  
Make sure the standby EMDP operates.

 (5)  
Make sure the STANDBY HYD LOW PRESSURE light goes out.

 (6)  
Put the FLT CONTROL A switch in the OFF position.

 (7)  
Make sure the standby EMDP stops.


 S 715-031
 S 215-032
 S 715-033
 S 715-034
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-15-00
 ALL  ú ú 01 Page 505 ú Jul 15/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
 (8)  S 865-035Open these circuit breakers: (a) P6-11 Panel 1) STBY HYD PUMP NORMAL (b) P6-12 Panel 1) STBY HYD PUMP ALTERNATE
 (9)  S 715-036Put the FLT CONTROL B switch in the STDBY RUD position.
 S 215-037

 (10) Make sure the STANDBY HYD LOW PRESSURE light comes on.
 NOTE:  It can be necessary to operate the rudder to remove pressure from the standby system.
 S 865-038
 (11) Close these circuit breakers:
 (a)  
P6-11 Panel 1) STBY HYD PUMP NORMAL

 (b)  
P6-12 Panel 1) STBY HYD PUMP ALTERNATE


 S 715-039
 (12)
 Make sure the standby EMDP operates.

 S 215-041

 (13)
 Make sure the STANDBY HYD LOW PRESSURE light goes out.

 S 715-042

 (14)
 Put the FLT CONTROL B switch in the OFF position.

 S 715-043

 (15)
 Make sure the standby EMDP stops.

 S 865-044

 (16)
 Open these circuit breakers:

 (a)  
P6-11 Panel 1) STBY HYD PUMP NORMAL

 (b)  
P6-12 Panel 1) STBY HYD PUMP ALTERNATE

 


 S 715-045
 (17) Put the arm switch for the ALTERNATE FLAPS (on the P5 Panel) in the ARM position.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 