(a) Make sure the pump continues to operate.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-15-31
ALL ú ú 01 Page 502 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 865-010
(5)
Put the GEN 1 or the left APU GEN switch to ON.
S 865-011
(6)
Put the FLT CONTROL B switch to OFF.
(a) Make sure the pump stops.
S 865-012
(7) Put the FLT CONTROL B switch to STDBY RUD.
(a) Make sure the pump starts.
S 865-013
(8) Put the FLT CONTROL B switch to OFF.
(a) Make sure the pump stops.
S 865-014
(9) Put the ALTERNATE FLAPS arm switch to ARM.
(a) Make sure the pump starts.
S 865-015
(10) Put the ALTERNATE FLAPS arm switch to OFF.
(a) Make sure the pump stops.
F. Do a Test of the Standby Hydraulic Pump (With Ground Power)
S 865-016
(1)
Supply external power to the No. 1 and No. 2 generator buses (Ref 24-22-00/201).
S 865-017
(2)
Put the FLT CONTROL B switch on the P5 panel to STBY RUD.
(a)
Make sure the standby pump starts.
(b)
Make sure the no-flow system pressure is between 2975 and 3100 psig.
S 865-018
(3) Open this circuit breaker and attach a DO-NOT-CLOSE tag:
(a) P6-4 Circuit Breaker Panel
1) AC INDICATION BUS NO. 1 C
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-15-31
ALL ú ú 01 Page 503 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(4) S 865-032Make sure the pump continues to operate.
(5) S 215-033Make sure the pressure gauge shows the correct indication.
(6) S 865-019Open this circuit breaker and attach a DO-NOT-CLOSE tag: (a) P6-12 Circuit Breaker Panel 1) STBY HYD PUMP (ALT)
S 865-034
(7)
Make sure the pump stops.
S 865-020
(8)
Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a) P6-4 Circuit Breaker Panel 1) AC INDICATION BUS NO. 1 C
S 865-035
(9)
Make sure the pump starts.
S 215-036
(10)
Make sure the pressure gauge shows the correct indication.
S 865-021
(11)
Put the FLT CONTROL B switch to OFF.
(a) Make sure the pump stops.
S 865-022
(12) Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a) P6-12 Circuit Breaker Panel 1) STBY HYD PUMP (ALT)
S 865-023
(13) Put the ALTERNATE FLAPS arm switch to ARM.
(a) Make sure the standby pump starts.
S 865-024
(14) Put the ALTERNATE FLAPS arm switch to OFF.
(a) Make sure the pump stops.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-15-31
ALL ú ú 01 Page 504 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 865-025
(15) Remove external ground power (Ref 24-22-00/201).
G. Put the Airplane Back to Its Usual Condition
S 865-026
(1)
Remove electrical power (Ref 24-22-00/201).
S 035-027
(2)
Remove the pressure gage from the pressure line.
S 435-028
(3)
Connect the hydraulic lines.
S 615-029
(4)
Do the servicing for the standby and system B hydraulic reservoirs (Ref 12-12-00/301).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(102)