S 032-093
(51)
Disconnect the pressure line of the standby system EMDP at the self-seal disconnect.
S 492-165
(52)
Connect the pressure line of the test bench to the self-seal disconnect which goes to the standby pressure module.
(53)
Pressurize the test bench.
S 862-096
(54)
Set the FLT CONTROL A or FLT CONTROL B switch on the P5 panel to the STBY RUD position.
(55)
Operate the rudder through two full cycles.
S 862-095
S 862-097
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-00-00
ALL ú ú 01 Page 212 ú Mar 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 862-098
(56)
Set the rudder to the middle position.
S 862-099
(57)
Set the FLT CONTROL A and FLT CONTROL B switches on the P5 panel to the OFF position.
S 862-100
(58)
Set the master arming switch for the ALTERNATE FLAPS, on the P5 panel, to the ARM position.
S 862-166
(59)
Set the ALTERNATE FLAPS switch on the P5 panel to the DOWN position.
S 862-102
(60)
Release the ALTERNATE FLAPS switch.
S 212-137
(61)
Make sure the leading edge slats extend fully.
S 862-103
(62)
Set the master arming switch for the ALTERNATE FLAPS, on the P5 panel, to the OFF position.
WARNING:_______ KEEP ALL PERSONS AND EQUIPMENT AWAY FROM THE LEADING EDGE
SLATS. THE LEADING EDGE SLATS CAN MOVE AUTOMATICALLY.
INJURIES TO PERSONS AND DAMAGE TO EQUIPMENT CAN OCCUR IF YOU DO
NOT DO THIS.
S 862-167
WARNING: KEEP PERSONS AND EQUIPMENT AWAY FROM ALL CONTROL SURFACES AND
_______ THE NOSE GEAR WHEN HYDRAULIC POWER IS SUPPLIED. THE AILERONS, ELEVATORS, RUDDER, FLAPS, SLATS, SPOILERS, STABILIZER , AND THE NOSE GEAR ARE SUPPLIED WITH POWER BY THE HYDRAULIC SYSTEMS. INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR WHEN HYDRAULIC POWER IS SUPPLIED.
CAUTION: DO NOT OPERATE THE EMDP FOR MORE THAN TWO MINUTES IF THE NO. 2
_______ FUEL TANK CONTAINS LESS THAN 250 GALLONS (1675 POUNDS/760 KILOGRAMS) OF FUEL. YOU MUST LET THE RESERVOIR TEMPERATURE DECREASE TO AMBIENT TEMPERATURE BEFORE YOU OPERATE THE PUMP AGAIN. DAMAGE TO EQUIPMENT CAN OCCUR IF YOU DO NOT DO THIS.
(63) Pressurize hydraulic system B with the EMDP (AMM 29-15-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-00-00
ALL ú ú 01 Page 213 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 862-105
(64)
Put the flap handle to the FLAP UP position. S 862-181
(65)
Remove power from hydraulic system B (AMM 29-15-00/201). S 862-179
(66)
Set the ALTERNATE FLAPS switch on the P5 panel to the ON position.
S 862-108
(67)
Push the ALTERNATE FLAPS switch on the P5 panel down and then release it.
S 212-136
(68)
Make sure the leading edge slats extend fully.
S 862-109
(69)
Set the ALTERNATE FLAPS switch on the P5 panel to the OFF position.
S 862-110
(70)
Release the pressure from the test bench.
WARNING:_______ KEEP ALL PERSONS AND EQUIPMENT AWAY FROM THE LEADING EDGE
SLATS. THE LEADING EDGE SLATS CAN MOVE AUTOMATICALLY.
INJURIES TO PERSONS AND DAMAGE TO EQUIPMENT CAN OCCUR IF YOU DO
NOT DO THIS.
S 862-168
WARNING: KEEP PERSONS AND EQUIPMENT AWAY FROM ALL CONTROL SURFACES AND
_______ THE NOSE GEAR WHEN HYDRAULIC POWER IS SUPPLIED. THE AILERONS, ELEVATORS, RUDDER, FLAPS, SLATS, SPOILERS, STABILIZER , AND THE NOSE GEAR ARE SUPPLIED WITH POWER BY THE HYDRAULIC SYSTEMS. INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR WHEN HYDRAULIC POWER IS SUPPLIED.
中国航空网 www.aero.cn