Make sure the ground locks are installed at the nose and main landing gear (AMM 32-00-01/201).

 S 846-008

 (2)  
Make sure the main landing gear has blocks installed.

 S 846-009

 (3)  
Remove the blocks and the tow bar from the nose landing gear.

 S 846-010

 (4)  
Make sure the thrust reverser cowls are closed.

 S 846-011

 (5)  
To use the ammeter procedure, do these steps:

 (a)  
Make sure the person in the flight compartment and the person on the ground can speak to each other (Interphone, radio).

 (b)  
Disconnect the electrical connector from the electric
 motor-driven pump (EMDP) for the B hydraulic system.


 (c)  
Connect one end of the cable assembly to the EMDP (Fig. 602).

 (d)  
Connect the other end of the cable assembly to the electrical connector (Fig. 602).

 CAUTION:_______PUT THE AMMETER IN THE SHORT CIRCUIT POSITION. THE CURRENT TO START THE EMDP IS APPROXIMATELY 180 AMPS. THIS WILL CAUSE DAMAGE TO THE AMMETER IF IT IS IN THE CIRCUIT.

 (e)  
Put the switch on the ammeter in the short-circuit position.

 


 S 846-012
 (6)  To use the flowmeter procedure, do these steps:
 (a)  Connect the hydraulic service cart to the ground service module for hydraulic system B. 1) Put the remote readout for the flowmeter in the control
 cabin (if you have one).
 2) Start the hydraulic service cart.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-00-00
 ALL  ú ú 02 Page 608 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 846-013
 (7)  To use the amp-clamp and multimeter procedure, do these steps:
 (a) Get access to the relay for the system B EMDP in the P6 panel.
 NOTE: The R317 relay is for system A EMDP and the R318 relay
____
 is for the system B EMDP.

 (b)  
Put the amp-clamp adapter around one of the three wires that go forward from the relay.

 (c)  
Connect the multimeter to the amp-clamp adapter.


 S 866-014
 (8)  Supply electrical power (AMM 24-22-00/201).
 NOTE: If you use a ground cart for electrical power, it must supply
____
 a voltage of 114 to 116 volts ac at 400 -5 Hz.

 Do not operate other electrical equipment during this test.
 S 846-016
 (9)  Make sure the No. 1 fuel tank (for the system A heat exchanger) and the No. 2 fuel tank (for the system B heat exchanger) have a minimum of 250 gallons (1675 pounds/760 kilograms) of fuel in them.
 NOTE: This is necessary to keep the hydraulic fluid cool.
____
 S 846-017
 (10)
 Put the parking brakes on.

 S 846-018

 (11)
 Put the FLT CONTROL and SPOILER switches (on the P5 panel) in the ON position.


 S 866-023
 WARNING: MAKE SURE THAT PERSONS AND EQUIPMENT ARE CLEAR OF ALL CONTROL
_______ SURFACES. THE AILERONS, RUDDER, ELEVATOR, FLAPS, SLATS, SPOILERS, LANDING GEAR, AND THRUST REVERSERS CAN MOVE QUICKLY. THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (12)
 Supply hydraulic power to systems A and B with the electric motor-driven pump or the hydraulic service cart (AMM 29-15-00/201).

 S 846-020

 (13)
 Operate the flaps until the temperature of the hydraulic fluid is more than 70°F.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 29-00-00
 ALL  ú ú 02 Page 609 ú Nov 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 846-021
 (14)
 Operate all of the control surfaces through a minimum of two cycles after the hydraulic fluid is warm.

 S 846-022

 (15)
 Do these steps to put the airplane in its initial condition:

 (a)  
Put the reverse thrust levers in the STOWED position.
 