29-34-31
ALL ú ú 01 Page 401 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
STANDBY SYSTEM
RESERVOIR
(REF)
STANDBY
EMDP
(REF)
STANDBY SYSTEM
PRESSURE MODULE
SEE A
FWD
WHEEL WELL
STANDBY SYSTEMLOW PRESSUREELECTRICAL PRESSURE MODULE
CONNECTOR SWITCH
CONNECTOR
ELECTRICAL
LOW PRESSURE
SWITCH
SEE B
BACKUP BACKUP
STANDBY SYSTEM RING O-RING RING
PRESSURE MODULE
LOW PRESSURE SWITCH B
FWD
STANDBY SYSTEM PRESSURE MODULE
A
Standby System EMDP Low Pressure Switch Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-34-31
ALL ú ú 01 Page 402 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
B. Access
(1) Location Zone
101 Control Cabin, LH
102 Control Cabin, RH
215 Keel Beam
C. Procedure
S 644-008
(1)
Apply assembly lube or hydraulic fluid to the O-ring and backup rings.
S 034-007
(2)
Install the O-ring and the backup rings in the low pressure switch.
S 644-006
(3)
Apply assembly lube or hydraulic fluid to the threads of the low pressure switch.
S 034-005
(4)
Remove the plug from the standby pressure module.
S 024-004
(5)
Install the low pressure switch.
(a)
Tighten the low pressure switch to 50-200 pound-inches.
(b)
Install a lockwire.
S 434-012
(6) Install the electrical connector on the low pressure switch.
D. Do a Check on the Low Pressure Switch
S 864-009
(1)
Supply electrical power (AMM 24-22-00/201).
S 864-013
(2)
Remove the DO-NOT-CLOSE tag and close this circuit breaker:
(a) P6-3 Circuit Breaker Panel
1) INDICATOR MASTER DIM BUS SECT 4
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-34-31
ALL ú ú 01 Page 403 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 864-014
(3)
Put the FLT CONTROL A or B switch, on the P5 panel, to the STDBY RUD position.
S 214-015
(4)
Make sure the STANDBY HYD LOW PRESSURE light, on the P5 panel, comes on.
S 864-016
(5)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a)
P6-11 Circuit Breaker Panel
1) STBY HYD PUMP NORMAL
(b)
P6-12 Circuit Breaker Panel
1) STBY HYD PUMP (ALT)
S 214-017
(6)
Make sure the STANDBY HYD LOW PRESSURE light goes off.
S 864-018
(7)
Put the FLT CONTROL A or B switch to the ON position.
(8)
Make sure the STANDBY HYD LOW PRESSURE light stays off.
(9)
Remove electrical power (AMM 24-22-00/201).
S 214-019
S 864-020
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-34-31
ALL ú ú 01 Page 404 ú Mar 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 液压 HYDRAULIC POWER(170)